12
Installation and base ground work for an outdoor unit
Base ground work
< When installing on the ground >
Drain hole
150 mm or more
< When installing on the roof >
Install the outdoor unit
horizontally on the ground
150 mm or more
f
The outdoor unit should be supported within the range of measurement below for base ground work.
(Unit : mm)
Anchor bolt position
360
384
620
940
330
f
When the outdoor unit needs to be supported, fix it with wire as shown in the picture.
- Slightly unwind the four screws on the cover top of the outdoor unit.
- Wind wires round the four screws and fasten the screws again.
- Fix the wires to the ground.
t
If the outdoor unit is not fixed securely, product may fall and it might cause loss of life or property damage.
t
Do not install the outdoor unit on a wood palette.
t
Fix the outdoor unit securely to the base ground with anchor bolts.
t
The manufacturer is not responsible for the damage occurred by not adhering to the standard of the installation.
t
To protect the outdoor unit from external condition such as rain, install it on the base ground and connect the
drain pipe to the drainage.
CAUTION