ENGLISH
B
A
D
C
B
A
D
C
B
A
D
C
Fixing the installation plate
You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing
the installation plate to a wall or a window frame, you must determine the position of the 2.56 inch (65 mm) hole through
which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
A
C
B
D
D
K
Direction of pipe
3. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter
of 2.56 inch (65 mm) so that it slants slightly downwards.
t3JHIU "
t-FGU #
t6OEFSTJEF@SJHIU $
t3FBS@SJHIUPSMFGU %
Wall
<0.79 inch
(20 mm)
Plastic
Anchor
4. Fix the indoor unit.
If you fix the indoor unit on a wall
(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.
If you fix the indoor unit on a window frame
(1) Determine the positions of the wooden uprights to be attached to the window frame.
(2) Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.
(3) Attach the installation plate to the wooden upright using tapping screws.
If you fix the indoor unit on a gypsum board
(1) Use stud finder to find out locations of the studs.
(2) Fix the plate hanger on two studs.
t *GZPVNPVOUUIFQMBUFUPBDPODSFUFXBMMVTJOHQMBTUJDBODIPSTNBLFTVSFUIBUHBQT
between the wall and the plate, created by projected anchor, is less than 0.79 inch
(20 mm).
t .BLFTVSFUPESJMMPOMZPOFIPMFBGUFS
choosing the direction of the pipe.
Unit : inch(mm)
Model
A
B
C
D
77
005/007/009
77
1.42(36) 2.36(60)
2.56(65) 1.42(36)
77
012/015
77
1.42(36) 4.72(120) 3.19(81) 1.42(36)
77
018/024/028
77
1.30(33) 4.33(110) 4.33(110) 1.30(33)
Pipe hole:Ø2.56 inch (Ø65 mm)
1. Disassemble the cover panel as described in page 8~9.
2. Remove the Hanger plate from the indoor unit.
(1) Unscrew 2 screws that fixes the Hanger plate to the indoor unit.
1VTIUIFIPPLT POUIFCPUUPNQBSUPGUIFJOEPPSVOJUVQUPSFMFBTFUIFJOTUBMMBUJPOQMBUFGSPNUIFIPPLTUIBUIPMETJU
(3) Pull the installation plate to release it completely from the indoor unit.
Screw
Pipe hole:Ø2.56 inch (Ø65 mm)
Pipe hole:Ø2.56 inch (Ø65 mm)
CAUTION
English-7