47
4. Combination Table
4. Combination Table
4-2 AJ050TXJ2KG/EU
COOLING
Outdoor unit
A
B
Cooling
Capacity
Capacity
Power
Consumption
Current
Effic. NOM.
Cooling.
At 35℃/27℃
SEASONAL
EFFICIENCY
(ACCORDING
EN14825)
SEER
Qce
W
W
W
A
A
B
MIN STD MAX MIN STD MAX MIN STD MAX
EER
Class
kWh
AJ050TXJ2KG 2 Unit
7
7
2000 2000 1300 4000 4700 350
980 1290
1.9
4.5
5.9
4.08
A+++
8.51
165
7
9
2040 2560 1300 4600 5200 350 1120 1520
1.9
5.1
7
4.11
A+++
8.51
189
7
12
1820 3180 1400 5000 5500 350 1230 1510
1.9
5.6
6.9
4.07
A+++
8.51
206
7
18
1430 3570 1400 5000 5500 350 1200 1510
1.9
5.5
6.9
4.15
A+++
8.51
206
9
9
2500 2500 1400 5000 5500 350 1220 1500
1.9
5.6
6.9
4.1
A+++
8.54
205
9
12
2080 2920 1400 5000 5500 350 1230 1510
1.9
5.6
6.9
4.07
A+++
8.51
206
9
18
1670 3330 1400 5000 5500 350 1230 1510
1.9
5.5
6.9
4.15
A+++
8.51
206
12
12
2500 2500 1400 5000 5500 350 1240 1520
1.9
5.7
7
4.03
A+++
8.51
206
12
18
2060 2940 1400 5000 5500 350 1240 1520
1.9
5.6
7
4.15
A+++
8.51
206
HEATING
Outdoor unit
A
B
Heating
Capacity
Capacity
Power
Consumption
Current
Effic. NOM.
Heating.
At 7℃/20℃
SEASONAL
EFFICIENCY
(ACCORDING
EN14825)
SCOP
P
design Qhe
W
W
W
A
A
B
MIN STD MAX MIN STD MAX MIN STD MAX
COP
Class
kW
kWh
AJ050TXJ2KG 2 Unit
7
7
2200 2200 1400 4400 4700 280 1010 1210
1.4
4.6
5.5
4.36
A++
4.61
3.05
927
7
9
2040 3060 1400 5100 5460 280 1310 1610
1.4
6
7.4
3.89
A++
4.61
4.21 1277
7
12
2020 3680 1400 5600 6300 280 1290 1710
1.4
5.9
7.8
4.34
A++
4.61
4.21 1277
7
18
1530 4170 1400 5600 6300 280 1270 1710
1.4
5.7
7.8
4.41
A++
4.61
4.07 1237
9
9
2850 2850 1400 5600 6300 280 1280 1700
1.4
5.9
7.8
4.38
A++
4.64
4.21 1270
9
12
2580 3120 1400 5600 6300 280 1290 1710
1.4
5.9
7.8
4.34
A++
4.61
4.21 1277
9
18
2020 3680 1400 5600 6300 280 1270 1710
1.4
5.7
7.8
4.41
A++
4.61
4.07 1237
12
12
2850 2850 1400 5600 6300 280 1300 1720
1.4
5.9
7.9
4.31
A++
4.61
4.21 1277
12
18
2280 3420 1400 5600 6300 280 1280 1720
1.4
5.8
7.9
4.38
A++
4.61
4.07 1237
NOTE
1
EER and COP declared only for the purpose of tax deductions in force at the time of the creation of this catalog.
2
The above is the value for connecting with the following indoor units.
- Wind Free(PRM) : AR07TXCAAWK, AR09TXCAAWK, AR12TXCAAWK
3
You can not connect a single unit.
4
Power consumption include indoor unit power.