38
Ins
tallation
Preparation
Step 1.1 Choosing the installation
location
Overview of installation location requirements
CAUTION
CAUTION
• Comply with the length and height limits described in
the figure above.
Step 1.2 Checking and preparing
accessories and tools
Accessories
Accessories in the indoor unit package
Installation plate (1)
Remote control (1)
Remote control battery
(2)
Cap screw (2)
Manual user & install (1)
NOTE
• A flare nut is attached to the end of each pipe of an
evaporator or a service port. Use flare nuts when
connecting the pipes.
• Wire assembly cables are optional. If they are not
supplied, use standard cables.
• The drain plug and the rubber legs are included only
when the air conditioner is supplied without assembly
pipes.
• If these accessories are supplied, they are in the
accessory package or outdoor unit package.
100 mm or more
Drain hose hole
You can select the direction of
draining (left or right).
Make a U-trap (A) on the
pipe (which is connected
to the indoor unit) at outer
wall and cut the bottom
part of the insulation
(about 10 mm) to prevent
rainwater from getting
inside through the
insulation.
Outdoor Unit
Outer wall
Indoor Unit
Cut insulation to have
rainwater drained
125 mm
or more
125 mm
or more