7
ENGLISH
◆
AJ024JCJ3CH
◆
Piping length and the height
◆
Piping outside diameter
※
The appearance of the unit may be different from the diagram depending on the model.
※
The appearance of the unit may be different from the diagram depending on the model.
Main power switch
A
B
C
(h) (H)
Make at least one round:
It will reduce noise and vibration
Indoor unit
Outdoor unit
Power supply Ø, V, Hz
77
007/009/012/018
77
AJ024JCJ3CH
1,208-230,60
Unit
Outside diameter
Liquid
Gas
77
007/009/012
77
1/4"
3/8"
77
018
77
1/4"
1/2"
1 Room max
length
3 Room total max
length
Max height between
indoor unit & outdoor unit
Max height between
indoor units
Dimension
25 m(82 ft)
70 m(230 ft)
15 m(49 ft)
7.5 m(25 ft)
Composition
A,B,C
A+B+C
(H)
(h)
CAUTION
3 m as minimum pipe length: It will reduce noise and
vibration.
※
AJ024JCJ3CH Outdoor unit cannot be connected to the following indoor unit combination.
-
77
024
77