E-
10
Operating Recommendation
If the air conditioner is used at...
Then...
Higher temperature
The automatic protection feature may be triggered
and the air conditioner stopped.
Lower temperature
A water leakage or some other malfunction may happen
if the heat exchanger freezes.
Higher humidity levels
Water may condense on and drip from the surface of the unit
if it is used for long periods.
The following table indicates the temperature and humidity ranges,
within which the air conditioner can be used.
Mode
Indoor
Temperature
Outdoor
Temperature
Indoor Humidity
Heating
28°C or less
0°C to 21°C approx.
-
Cooling
21°C to 32°C approx.
21°C to 54°C approx.
80% or less
Here are a few recommendations that you should follow when using
your air conditioner.
Topic Recommendation
If a power failure occurs when the air conditioner is operating,
the unit is switched off. When the power returns,
the air conditioner starts up again automatically.
Power failure
The air conditioner circulates warm air to heat your room;
as a result, some time will be required after starting
the air conditioner to warm the entire room. If necessary,
set the air conditioner going a short time before you wish
to use the room.
Warm air
circulation
Temperature and Humidity Ranges