19
ENGLISH
Connecting communication line and wired remote controller
In case of 2 indoor units connection
Operation and specification
- The two, the three, or the four sets of the indoor units with DPM installation which are controlled by wired and wireless
remote controller work equally. (All controls such as ON/OFF, cooling/heating/dehumidification/ventilation, high/ medium/
low wind, fixing louver angle/swing are equally applied.)
- Thermo OFF which stops when indoor temperature reaches set temperature works by the average sensor value of the
indoor temperature of the all indoor units.
- When one of the several indoor units has a problem, they protect operation or stop working.
Instruction for installation and operation
- You should install the DPM according to the above installation specification and eliminate the factors that give electrical
load to the both indoor units when installing and operating. (Heater / window / front door / ventilation / partition that divides
space)
- You should provide sufficient instructions about the operation method and specification features to users and fill in caution
phrases on wired remote controller when necessary.
▶
<The air-conditioners in this area are special type to be controlled simultaneously.>
Set up indoor quantity by key switch(K1, K2)
- Press and hold K1 switch to enter the setting mode on the number of the installed indoor unit : Check “A0” sign on
7-segment
▶
Press K2 switch to set the number of the installed indoor unit :
Ex) If there are two indoor units, press K2 switch twice, and check "A2" sign on 7-segment.
If there are three indoor units, press K3 switch three times, and check "A3" sign on 7-segment.
If there are four indoor units, press K4 switch four times, and check "A4" sign on 7-segment.
▶
Press K1 switch to complete setting the number of the installed indoor unit : Check "AA" sign on 7-segment.
Outdoor
unit
F1/F2
L/N
Indoor unit #1
F1/F2
F1/F2
Indoor unit #2
L/N
L/N
Remote control
The wired remote controller can be used with any of the DPM indoor units.