Samsung Electronics
7-1
*OEPPS6OJU
0VUEPPS6OJU
)FBUFYDIBOHFS
&WBQPSBUPS
-JRVJEQJQF
(BTQJQF
XBZWBMWF
XBZWBMWF
&MFDUSPOJDFYQBOTJPOWBMWF
$PNQSFTTPS
0JMTFQBSBUPS
XBZWBMWF
$PPMJOH
)FBUJOH
-FBLDIFDLQPJOUT
"VYBDDVNVMBUPS
'BO
)FBUFYDIBOHFS
&WBQPSBUPS
'BO
7. Preference Sheet
7-1 Refrigerating Cycle Diagram
■
CONDENSER
High temperature and high pressure gas state coolant discharged from the compressor is converted to a liquid state as it
is cooled down by the heat emission in the outdoor condenser unit, and sent to the evaporator.
■
COMPRESSOR
Low temperature and low pressure coolant is compressed and sent to the cycling system
■
EVAPORATOR
Liquid coolant sucked in through the capillary tubes cools down the room by absorbing the sur-
rounding heat as it evaporates (converting from liquid to gas). (Absorbing heat required for evaporation)
■
SERVICE VALVE
You can open the valve by turning the need valve counterclockwise using hex wrench, and it is used for vacuum, gas
purging, coolant injection, coolant purging, and indoor-outdoor unit connection.
■
ACCUMULATOR
Accumulator prevents the flow of liquid-state coolant into the compressor. (Liquid-state coolant flowing into the com-
pressor will overload the compressor.)