T
ro
ubl
eshooting
4-14
S
ams
u
ng
El
ectronics
4-2-4 Wired remote controller
- I
f
an
error
occ
u
rs
, (
)
icon
wi
ll b
e
disp
l
ayed
on
the
wired
remote
contro
ll
er.
-
Press
the
T
est
bu
tton
to
see
the
error
code.
&SSPSNPEF
Contents
.FBTVSF
Product operation in
error condition
&SSPSUZQF
Outdoor unit/
Compressor/Indoor unit
I
ndoor
u
nit
comm
u
nication
error
Chec
k
the
comm
u
nication
ca
bl
e
of
indoor
u
nit.
Chec
k
the
DC
o
u
tp
u
t
v
o
l
tage
at
the
comm
u
nication
termina
l
.
Operation
Off
Comm
u
nication
error
D
u
p
l
icated
address
setting
error
Chec
k
address
setting
of
I
ndoor
u
nits.
Operation
Off
Comm
u
nication
error
No
response
error
address
from
indoor
u
nit
Chec
k
indoor
u
nit
'
s
qu
antity
setting
in
o
u
tdoor
u
nit.
Chec
k
e
l
ectriac
l
connection
and
setting.
Operation
Off
Comm
u
nication
error
I
ndoor
temperat
u
re
sensor
(
open
/
short
error)
Chec
k
indoor
u
nit
room
temperat
u
re
sensor.
Chec
k
indoor
u
nit
PCB
connector
CN
41
.
(W
hite)
Operation
Off
I
ndoor
sensor
error
I
ndoor
u
nit
Ev
a
I
n
sensor
(
Open
/S
hort)
Chec
k
indoor
u
nit
pipe
sensor.
Chec
k
indoor
PCB
connector
CN
41
.
(W
hite)
Operation
Off
I
ndoor
sensor
error
I
ndoor
f
l
oating
switch
secondary
detection
Chec
k
indoor
u
nit
f
l
oat
sensor.
Chec
k
indoor
PCB
connector
CN5.
(bl
ac
k
)
Operation
Off
S
e
l
f
diagnostic
error
I
ndoor
/
o
u
tdoor
comm
u
nication
error
(1
min)
Chec
k
the
comm
u
nication
connection
b
etween
indoor
and
o
u
tdoor
u
nits.
Chec
k
the
power
l
ine
and
comm
u
nication
ca
bl
e
connection
stat
u
s
Operation
Off
Comm
u
nication
error
Comm
u
nication
error
b
etween
indoor
/
o
u
tdoor
I
N
V
l
MA
I
N
M
I
COM
(1
min)
Chec
k
MA
I
N
M
I
COM
.
Chec
k I
N
VE
R
TE
R
M
I
COM.
-
Comm
u
nication
error
O
u
tdoor
temperat
u
re
sensor
error
Chec
k
sensor
connection
stat
u
s.
Chec
k
sensor
l
ocation.
Chec
k
sensor
resistance.
Operation
Off
O
u
tdoor
sensor
error
COND
temperat
u
re
sensor
error
Chec
k
sensor
connection
stat
u
s.
Chec
k
sensor
l
ocation.
Chec
k
sensor
resistance.
Operation
Off
O
u
tdoor
sensor
error
[I
n
v
erter
] E
mission
temperat
u
re
sensor
error
Chec
k
sensor
connection
stat
u
s.
Chec
k
sensor
l
ocation.
Chec
k
sensor
resistance.
Operation
Off
O
u
tdoor
sensor
error
Detection
of
I
ndoor
F
ree
z
ing
(
when
Comp.
S
tops)
Chec
k
whether
the
indoor
u
nit
air
inta
k
e
is
bl
oc
k
ed.
Chec
k
the
operation
of
the
indoor
fan.
Operation
Off
O
u
tdoor
u
nit
protection
contro
l
error
Protection
of
O
u
tdoor
O
v
er
l
oad
(
when
Comp.
S
tops)
Chec
k
sensor
connection
stat
u
s.
Chec
k
sensor
l
ocation.
Chec
k
sensor
resistance.
Operation
Off
O
u
tdoor
u
nit
protection
contro
l
error
E
mission
temperat
u
re
e
x
cessi
v
e
l
y
high
No
error.
(
D
IS
C
H
AR
GE
temperat
u
re
contro
l
)
-
O
u
tdoor
u
nit
protection
contro
l
error
H
igh
press
u
re
bl
oc
k
age
error
(
Refrigerant
comp
l
ete
l
y
L
ea
k
age
error)
Chec
k
whether
the
o
u
tdoor
u
nit
ser
v
ice
v
a
lv
e
is
open.
Chec
k
the
connection
of
the
pipes.
Chec
k
the
operation
of
the
EEV
.
Chec
k
for
refrigerant
l
ea
k
age.
(
Comp
l
ete
l
y
l
ea
k
age).
Operation
Off
S
e
l
f
diagnostic
error
H
eating
operation
bl
oc
k
ed
Chec
k
the
operation
setting
state.
Chec
k
temperat
u
re
sensor.
Operation
Off
S
e
l
f
diagnostic
error
Coo
l
ing
operation
bl
oc
k
ed
Chec
k
the
operation
setting
state
.
Chec
k
temperat
u
re
senso.
Operation
Off
S
e
l
f
diagnostic
error
O
u
tdoor
fan
1
error
Chec
k
inp
u
t
power
connection
stat
u
s.
Chec
k
the
connection
stat
u
s
b
etween
the
motor
and
o
u
tdoor
u
nit
PCB.
Chec
k
indoor
/
o
u
tdoor
f
u
se.
Operation
Off
S
e
l
f
diagnostic
error
[I
n
v
erter
]
Compressor
start
u
p
error
Chec
k
the
compressor
connection
stat
u
s.
Chec
k
the
resistance
b
etween
difference
phases
of
the
compressor.
Operation
Off
O
u
tdoor
u
nit
protection
contro
l
error
[I
n
v
erter
] T
ota
l
c
u
rrent
error
/
P
F
C
o
v
er
c
u
rrent
error
Chec
k
the
inp
u
t
power
Chec
k
the
coo
l
ant
charging
stat
u
s
Chec
k
the
norma
l
operation
of
o
u
tdoor
fan
Operation
Off
O
u
tdoor
u
nit
protection
contro
l
error