English
Model
AC018KN4DCH
AC024KN4DCH
AC030KN4DCH
AC036KN4DCH
AC042KN4DCH
AC048KN4DCH
Chassis
Small
Large
Net dimension
(W × D × H)
mm
(in.)
947 x 947 x 281
(37.28 x 37.28 x
11.06)
947 x 947 x 281
(37.28 x 37.28 x
11.06)
947 x 947 x 365
(37.28 x 37.28 x
14.37)
947 x 947 x 365
(37.28 x 37.28 x
14.37)
947 x 947 x 365
(37.28 x 37.28 x
14.37)
947 x 947 x 365
(37.28 x 37.28 x
14.37)
Net weight
kg
(lb)
21.0 (46.3)
21.0 (46.3)
24 (53.9)
24 (53.9)
24 (53.9)
24 (53.9)
Liquid pipe
connection
mm
(in.)
6.35 (1/4)
6.35 (1/4)
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
Gas pipe
connection
mm
(in.)
12.7 (1/2)
15.88 (5/8)
15.88 (5/8)
15.88 (5/8)
15.88 (5/8)
15.88 (5/8)
Drain hose
connection
mm
(in.)
Outer diameter : ø32.0 (1.26"), inner diameter : 26.5 (1.04")
A
A : 1500 mm or more
A
A
A
'C'
Indoor unit
2500 (98.5) or more
Obstruction
20 (0.79 )
1500 (59.10)
or more
10 (0.39)
Model
AC018KN4DCH
AC024KN4DCH
AC030KN4DCH
AC036KN4DCH
AC042KN4DCH
AC048KN4DCH
C
mm (in.)
261 (10.27)
261 (10.27)
345 (13.58)
345 (13.58)
345 (13.58)
345 (13.58)
Spacing requirements
Unit: mm (inch)
•
The circular panel is by default available in exposed
installation.
•
Make inspection holes on the ceiling for easier
installation and maintenance, as shown in the
following table. (The size of an inspection hole must
be at least 450 mm x 450 mm.)
•
A suspended ceiling structure can substitute for the
inspection holes.
Category
Inspection hole
Recessed installation
Exposed
installation
Integrated
suspended
Square panel
1 ea
-
Circular panel
2 ea
•
For the recessed installation of the circular panel
Refrigerant
pipe
Connection part of the
drain hose
Indoor unit
display
Inspection hole
1050 (41.37)
883 (34.79)
ø1010 to 1020
(ø39.76 to 40.16)
Ceiling opening diameter
ø1010 to 1020
(ø39.76 to 40.16)
Inspection hole
NOTE
The clearance between the panel and the inspection hole
is 15 to 20 mm (0.59 to 0.79 in.) on a side.