Connecting the cable
Two electronic cables must be connected to the outdoor unit.
f
f
The connection cord between indoor unit and outdoor unit .
f
f
The power cable between outdoor unit and auxiliary circuit breaker .
f
f
Be sure to run the power supply cable and the communication cable through
electrical conduit as seen in the picture .
f
f
Protect the power and communication cable using the protection tube
individually .
f
f
Make a knockout hole .
f
f
After making a knockout hole, apply rust resisting paint around the hole .
f
f
Secure the cable tube to the outdoor knockout using the CD connector and
bushing .
• During the unit installation make first refrigerant connections and then
electrical connections . If unit is uninstalled first disconnect electrical
cables, then refrigerant connections .
• Connect the air conditioner to grounding system before performing
the electrical connection .
• When installing the unit, you shouldn't use inter connection wire .
CAUTION
• In case of extending the electric wire, please DO NOT
use a round-shaped pressing socket .
- Incomplete wire connections can cause electric
shock or a fire .
WARNING
Conduit
Example of Air Conditioner System
When using ELCB for 1 phase
ELCB
1
Indoor Unit
Power cable
Outdoor Unit
Communication cable
Grounding
OR
Power cable
Communication cable