Troubleshooting
4-42
Samsung Electronics
K4 short
push
Display contents
SEG1
SEG2
SEG3
SEG4
Unit
1
Order frequency
1
Hundreds digit
Tens digit
Units digit
Hz
2
Current frequency
2
Hundreds digit
Tens digit
Units digit
Hz
3
The number of preset indoor
units
3
Hundreds digit
Tens digit
Units digit
EA
4
Ambient temperature sensor
4
Hundreds digit or - ¹⁾
Tens digit
Units digit
℃ or ℉ ²⁾
5
Compressor discharge sensor
5
Hundreds digit
Tens digit
Units digit
℃ or ℉ ²⁾
6
Eva-Mid sensor
6
Hundreds digit or - ¹⁾
Tens digit
Units digit
℃ or ℉ ²⁾
7
Condensor sensor
7
Hundreds digit or - ¹⁾
Tens digit
Units digit
℃ or ℉ ²⁾
8
Current
8
Tens digit
Units digit
The first place of
decimals
A
9
Outdoor fan RPM
9
Thousands digit
Hundreds digit
Tens digit
rpm
10
Target discharge temperature
A
Hundreds digit or - ¹⁾
Tens digit
Units digit
℃ or ℉ ²⁾
11
EEV
B
Hundreds digit
Tens digit
Units digit
step
12
The capacity sum of indoor
units
C
Tens digit
Unit digit
The first place of
decimals
kW or
kBtu/h ³⁾
13
Protective control
D
0: Cooling
1: Heating
Protective control
0: No Protective control
1: Freezing
2: Non-stop defrosting
3: Over-load
4: Discharge
5: Total electric current
Frequency status
0: Normal
1: Hold
2: Down
3: Up_limit
4: Down_limit
-
14
IPM temperature
E
Hundreds digit or - ¹⁾
Tens digit
Units digit
℃ or ℉ ²⁾
15
The number of connected
indoor units
F
Hundreds digit
Tens digit
Units digit
EA
16
ESC EEV(CAM)
G
Hundreds digit
Tens digit
Units digit
step
17
ESC IN sensor
H
Hundreds digit or - ¹⁾
Tens digit
Units digit
℃ or ℉ ²⁾
18
ESC OUT sensor
I
Hundreds digit
or - ¹⁾
Tens digit
Units digit
℃ or ℉ ²⁾
19
View mode end
BLANK
BLANK
BLANK
BLANK
1) Sub-zero temperatures are expressed as a minus, instead of hundreds digit.
2) The temperature unit can be switched between Celsius and Fahrenheit through Setting outdoor unit option switches.
(Default value is Celsius.)
3) If the temperature unit is set to Fahrenheit through Setting outdoor unit option switches, the value is expressed
in the unit of kBtu/h.
■ View Mode
Test operation mode and check mode (Cont.)