Troubleshooting
4-16
Samsung Electronics
Option
SEG13
SEG14
SEG15
SEG16
SEG17
SEG18
Function
Page
Use of external control
Setting the output of
extermal control
Reserved
Buzzer control
Maximum filter
usage time
4)
Indication
and details
Indication Details Indication
Details
Indication
Details
Indication
Details
Indication
Details
2
0
Disuse
Sub,
Existing
control
0
Thermo on
0
Use of buzzer
2
1000
hours
1
On/Off
2
Off
3
Window
On/Off
4
Disuse
Main,
Existing
control
5
On/Off
6
Off
7
Window
On/Off
8
Disuse
Sub,
Reverse
control
1
Operation
On
1
Disuse of
buzzer
6
2000
hours
9
On/Off
A
Off
B
Window
On/Off
C
Disuse
Main,
Reverse
control
D
On/Off
E
Off
F
Window
On/Off
Option
SEG19
SEG20
SEG21
SEG22
SEG23
7)
SEG24
Function
Page
Individual control with
remote control
5)
Heating setting
compensation
6)
Reserved
Setting the MDS Kit installation option
Reserved
Indication
and details
Indication Details Indication
Details
Indication
Details
Indication
Details
3
0 or 1
Indoor1
0
Default
0
Disuse (Soft Off+Hard off)
Standard
1
Off after 20 min.
(Soft Off+Hard off)
2
Off after 40 min.
(Soft Off+Hard off)
3
Off after 80 min.
(Soft Off+Hard off)
2
Indoor2
1
3.6˚F(2˚C)
Premium
4
Off after 20 min.
(Soft Off+Hard off)
5
Off after 40 min.
(Soft Off+Hard off)
6
Off after 80 min.
(Soft Off+Hard off)
3
Indoor3
2
9˚F(5˚C)
Standard
7
Off after 20 min.
(Soft Off only)
8
Off after 40 min.
(Soft Off only)
9
Off after 80 min.
(Soft Off only)
4
Indoor4
Premium
A
Off after 20 min.
(Soft Off only)
B
Off after 40 min.
(Soft Off only)
C
Off after 80 min.
(Soft Off only)
• 1) SEG4
By SEG4 setting, Minimizing fan operation when thermostat is off.
- Fan operates for 20 seconds at an interval of 5 minutes in heat mode.
- Fan stops or operates Ultra low in Cooling when thermostat is off.
• 2) SEG8
Even if you set the Use of drain pump option to 0, it is utomatically set to 2 (the drain pump is used with 3 minute delay).
• 3) SEG11
Compensation of the wind-free fan RPM option adjusts 20 rpm per 1 step.
• 4) SEG18
If you set the Maximum filter usage time option to a value other than 2 and 6, it is automatically set to 2 (1000 hours).
• 5) SEG20
If you set the Individual control with remote control option to a value other than 0 to 4, it is automatically set to 0 (Indoor 1)
• 6) SEG21
Default value of Heating setting compensation is 9°F(5℃).
• 7) SEG23
Soft Off
: The indoor unit turns off its operation at the indicated time in the table for Installation Option after its final motion detection. But, it turns on again if the
MDS detects motion.
Hard Off
: Designated time after SOFT OFF, it cannot turn on automatically when it detects motion. Users should control to turn on the indoor unit with remote
control, etc.