29
English
Installation Pr
oc
edur
e
Steps
Remote control display
19
Set the SEG23 and SEG24 values:
a
Set the SEG23 value by pressing the
(Low Fan) button repeatedly until the
value you want to set appears on the remote control display.
SEG23
b
Set the SEG24 value by pressing the
(High Fan) button repeatedly until the
value you want to set appears on the remote control display.
When you press the
(Low Fan) or
(High Fan) button, values appear in the
following order:
SEG24
3
Check whether the option values that you have set are
correct by pressing the
(Mode) button repeatedly
[SEG2, SEG3]
[SEG11, SEG12]
[SEG21, SEG22]
[SEG4, SEG5]
[SEG14, SEG15]
[SEG23, SEG24]
[SEG6, SEG8]
[SEG16, SEG17]
[SEG9, SEG10]
[SEG18, SEG20]
4
Save the option values into the indoor unit:
Point the remote control to the remote control sensor
on the indoor unit and then press the
(Power)
button on the remote control twice. Make sure that
this command is received by the indoor unit. When it is
successfully received, you can hear a short sound from
the indoor unit. If the command is not received, press
the
(Power) button again.
5
Check whether the air conditioner operates in
accordance with the option values you have set:
a
Reset the indoor or outdoor unit.
• Indoor unit : Press the
(Set) and
(Low Fan) buttons on the remote control
simultaneously for 4 seconds.
• Outdoor unit : Press the K3 button.
b
Remove the batteries from the remote control,
insert them again, and then press the
(Power)
button on the remote control.
Setting the indoor unit addresses
Option No. for an indoor unit address:
0AXXXX-1XXXXX-2XXXXX-3XXXXX
Before installing an indoor unit, be sure to set an address
for the indoor unit by taking the following steps:
1
Make sure that the power is supplied to the indoor
unit. If the indoor unit is not plugged in, it must include
a power supply.
F1
F2
L
N
Indoor unit
Summary of Contents for AC TN4PKC Series