39
ENGLISH
4. Press
the /
button to set the installation option code in order. Press
button to go to the next page.
SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
0
2
RESERVED
Exterior temperature
sensor
Central control
RESERVED
SEG7
SEG8
SEG9
SEG10
SEG11
SEG12
1
RESERVED
RESERVED
Use of Heater
Controller variables
for auxiliary heater
Master / Slave
SEG13
SEG14
SEG15
SEG16
SEG17
SEG18
2
External control
External control
output
RESERVED
Buzzer
RESERVED
SEG19
SEG20
SEG21
SEG22
SEG23
-
3
Individual control of a
remote controller
Heating setting
compensation
RESERVED
RESERVED
-
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
Option
SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
Explanation
PAGE
MODE
RESERVED
Use of external
temperature sensor
Use of central control
RESERVED
Indication
and Details
Indication Details Indication Details
Indication
Details
Indication
Details
0
2
0
Disuse
0
Disuse
1
Use
1
Use
Option
SEG7
SEG8
SEG9
SEG10
SEG11
SEG12
Explanation
PAGE
RESERVED
RESERVED
Use of Heater
Controller variables for auxiliary
heater
Master / Slave
Indication
and Details
Indication Details
Indication
Details
Indication
Details
Indication Details
1
0
Disuse
Set
temperature
for auxiliary
heat on
Time delay
for auxiliary
heat on
0
slave
1
Use
0
No temperature
offset
No delay
1
master
1
No temperature
offset
10 minutes
-
-
2
Use
(Heater
Time
Delay)
2
No temperature
offset
20 minutes
3
2.7°F (1.5°C)
No delay
4
2.7°F (1.5°C)
10 minutes
5
2.7°F (1.5°C)
20 minutes
6
5.4°F (3°C)
No delay
7
5.4°F (3°C)
10 minutes
8
5.4°F (3°C)
20 minutes
9
8.1°F (4.5°C)
No delay
A
8.1°F (4.5°C)
10 minutes
B
8.1°F (4.5°C)
20 minutes
C
10.8°F (6°C)
No delay
D
10.8°F (6°C)
10 minutes
E
10.8°F (6°C)
20 minutes
jhjGvktG}Tho|ptuv{jvkllunUGGGZ`