7
| DOC9055M
Truck Master 3400
2.2 Specifications
Description
Minimum
Maximum
Ambient temperature, operation
Below 0°C - see chapter 5.3
-20°C
55°C
Ambient temperature, storage
-20°C
55°C
Humidity
-
100%
Intake temperature, suction side
-
60°C
Intake temperature, water
-
60°C
Water pipe connection, dimension
1¼”
-
Water pipe connection, length
-
6 m
Noise level
-
80 dB(A)
Water volume
-
52 L
Maximum radial load on drive shaft
-
14000 N
Heat input for cooler calculation
1100 rpm
48 kW
-
1200 rpm
57 kW
-
1300 rpm
68 kW
-
1400 rpm
80 kW
-
Revolutions
1100 rpm
1400 rpm
Pressure
150 mbar abs.
0,75 bar(g)
Lubricating grease
Type of grease
SKF LGWA2
Automatic lubrication
SKF LAGD 125/WA2
Weight
531 kg
A failure to meet these specifications may result in damage to the pump