21
| DOC9055M
Truck Master 3400
5 SERVICE, OPERATION, MAINTENANCE AND
INSPECTION INTERVALS
A failure to observe the inspection intervals described in table below may result in
damage to the pump
Section
Operation
Interval
5.1
Drain liquid separator and pump to remove contaminants
Daily
5.2
Check grease cartridges (if equipped)
Weekly
5.3
Winterization
When below 0°C
5.4
Lubrication of bearings
Per 500 duty hours
5.5
Inspection and cleaning of service liquid’s supply pipe
Monthly
5.6
Inspection and cleaning of internal channels
Monthly
5.2 Check grease cartridges
DOC3707
If the pump is equipped with an automatic lubrication feature. It must be inspected and
replaced as needed.
When the pump is commissioned for the first time, the cartridges must be activated by
turning the arrow in the clockwise direction.
The cartridge is set to 12, which corresponds to an emptying time of 12 months.
The cartridge must be replaced when empty.
It is only allowed to use automatic lubricator of type
LAGD 125/WA2
.
5.1 Draining the liquid separator and the pump
While the pump is stopped, the liquid separator must be drained to remove contaminants.
Drain the pump in C
1
or C
2
, see chapter 2.5.
5.3 Winterization
If the pump needs to be used at a temperature below freezing point of the water, it is necessary to protect
the water from freezing by adding anti freeze liquid.