background image

4

STEREO/MONO

CROSSOVER

MASTER CONTROLS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

23

24

25

26

19

20

21

22

Controls and Functions

FR

ONT P

ANEL LA

Y

OUT

1 INPUT 

GAIN

- Used to adjust the input gain from

–12dB to +12dB. 

2

INPUT METER (CH 1)

– Four-segment LED VU

meter displays the amount of level present at the

Channel 1, or left, input.

3

DELAY (CH 1)

– This control is used to adjust the

delay line from 0 to 2ms, for time aligning the low

frequency output.

4

LOW GAIN (CH 1)

- Adjusts the output level of the

LOW frequency band for the left in stereo 2-way

mode, or for the LOW band in mono 3-way mode. 

5

FREQUENCY (CH 1)

- This control sets the

crossover point dividing the frequency bands

from low-to-high in stereo 2-way mode, or from

low-to-mid when you are operating in mono 3-

way mode.

6

HIGH GAIN (CH 1)

- Adjusts the output level of

the HIGH frequency band for Channel 1 in stereo

2-way mode, or for the MID band in mono 3-way

mode.

7

PHASE Switch (MID / HIGH CH1)

- Used to invert

the phase on the left HIGH output in stereo 2-way

mode, or the MID output in mono 3-way mode.

8

MUTE Switch (MID / HIGH CH 1)

- This switch is

used to defeat the output for the HIGH frequency

output when operating in stereo 2-way mode, or

to defeat the MID frequency output when operat-

ing in mono 3-way mode.

OPERATING MODE SELECTOR

- Selects one of the 2

operating modes, 2-way stereo or 3-way mono.

10

PHASE Switch (HIGH CH2)

- Used to invert the phase

on the right HIGH output in stereo 2-way mode, or the

HIGH output when operating in mono 3-way mode.

11

MUTE Switch (HIGH CH 2)

- This switch is used to

defeat the output for the HIGH frequency output when

operating in stereo 2-way mode, or to defeat the HIGH

frequency output when operating in mono 3-way mode

12

INPUT METER (CH 2)

– Four-segment LED VU meter dis-

plays the amount of level present at the Channel 2, or

lright input.

13

INPUT GAIN

- Used to adjust the input level from –12dB

to +12dB. 

14

DELAY (CH 2)

– This control is used to adjust the delay

line, from 0 to 2ms, for time aligning the channel 2 low

frequency output. This control has no effect when oper-

ating in stereo 3-way mode.

15

LOW GAIN CONTROL (CH 2)

- Adjusts the output level

of the LOW frequency band for right in stereo 2-way

mode. This control has no effect when operating in

stereo 3-way mode.

16

FREQUENCY CONTROL (CH 2)

- This control sets the

crossover point dividing the frequency bands from low-

to-high in stereo 2-way mode, or from mid-to-high

when you are operating in mono 3-way mode.

17

HIGH GAIN CONTROL (CH 2)

- Adjusts the output level

of the HIGH frequency band for Channel 2 in stereo 2-

way mode, or for the HIGH band in mono 3-way mode.

18

MAIN POWER Switch

- When this switch is engaged, the green

LED will illuminate indicating that the S 2-way is powered up and

ready for operation.

19

HPF Switch (CH1)

- Engages the High Pass Filter, or low cut, rolling

off the low frequencies at 25Hz,  by12 dB per octave, helping to

reduce unwanted low frequency rumble.

20

RANGE Switch (CH 1)

– This switch is used to change the frequen-

cy range of the crossover filter from 35 Hz to 800 Hz, or from 350

Hz to 8 kHz when the switch is engaged.

21

PHASE Switch (LOW CH1)

- Used to invert the phase on the

leftLOW output in stereo 2-way mode, or the LOW output when

operating in mono 3-way mode.

22

MUTE Switch (LOW CH1)

- This switch is used to defeat the LOW

frequency output when operating in stereo 2-way mode, or to

defeat the LOW frequency output when operating in mono 3-way

mode.

23

PHASE Switch (LOW  CH2)

- Used to invert the phase on the right

LOW output in stereo 2-way mode. This control has no effect when

operating in stereo 3-way mode.

24

MUTE Switch (LOW CH 2)

- This switch is used to defeat the out-

put for the right LOW frequency output when operating in stereo

2-way mode. This control has no effect when operating in stereo 3-

way mode.

25

HPF Switch (CH2)

- Engages the High Pass Filter, or low cut, rolling

off the low frequencies at 25Hz,  by12 dB per octave, helping to

reduce unwanted low frequency rumble. This control has no effect

when operating in stereo 3-way mode.

26 

RANGE Switch (CH 2)

– This switch is used to change the frequen-

cy range of the crossover filter from 35 Hz to 800 Hz, or from 350

Hz to 8 kHz when the switch is engaged.

Summary of Contents for S Class

Page 1: ...S C l a s s S i g n a l P r o c e s s o r s STEREO MONO CROSSOVER...

Page 2: ...objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita que...

Page 3: ...on 7 8 S 2 way Controls 9 S 2 Way System Set Ups Mono 3 way Operation 10 SETTING UP THE S 2 way USING A REAL TIME ANALYZER 11 12 S 2 way Connections 13 Block Diagram 14 Specifications 15 Notes 16 Copy...

Page 4: ...electronic crossover solution which will give you precise control and superior sound from your loudspeaker system In these pages you ll find a detailed description of the features of the S 2 way elect...

Page 5: ...ows to adjust frequency range of the filter allowing you to change from mid band to high band The four segment LED Input Gain meter allows you to monitor the signal level and make easy gain adjustment...

Page 6: ...hannel 2 low frequency output This control has no effect when oper ating in stereo 3 way mode 15 LOW GAIN CONTROL CH 2 Adjusts the output level of the LOW frequency band for right in stereo 2 way mode...

Page 7: ...utput G CHANNEL 1 INPUT MONO INPUT XLR bal anced line input A AC INLET IEC standard ac power cable connec tor with external fuse B CHANNEL 2 HIGH OUTPUT MONO HIGH OUT PUT XLR balanced line output C CH...

Page 8: ...band that the control The 3 way parameters for these switches and control knobs are indicated by the outlined box MONO 3 WAY INDICATORS Because the S 2 way can be configured to operate in either ster...

Page 9: ...m other gear in your system and help prevent unnecessary pops that can sometimes cause speaker damage Connect both sets of inputs and outputs to the designated connectors on the rear panel For a detai...

Page 10: ...raise the output faders until you see the Input Meter LED s begin to light Slowly raise the S 2 way s Input Gains until the Input Meters read 0dB Now raise your power amps to their normal operating le...

Page 11: ...ing speaker stacks S 2 way Controls HIGH PASS FILTER The S 2 way incorporates a HPF High Pass Filter which when engaged activates a low frequency roll off at 25 Hz By using the HPF you elimi nate the...

Page 12: ...g the mid and high by using Channel 2 s crossover FREQ control Now adjust the first gain control on Channel 1 to set the level of the LOW frequency output Next adjust the second gain control on Channe...

Page 13: ...nd compression drivers mounted on a large horn With no correction the low frequency signal can be traveling through the air 2 to 24 in front of the high frequencies and thereby reaching the listeners...

Page 14: ...wave tuned to the crossover frequency or connect the signal from a pink noise generator to your loudspeaker system either from your mixer or directly in the S 2 way s input Now turn off the Low Frequ...

Page 15: ...13 Connections Unbalanced 1 4 Connector Balanced TRS 1 4 Connector XLR Balanced Wiring Guide...

Page 16: ...14 Block Diagram...

Page 17: ...Type Linkwitz Riley 24 dB Octave Crossover 1 Channel 1 35 to 800Hz 350 to 8kHz with 10X multiplier Crossover 1 Channel 2 35 to 800Hz 350 to 8kHz with 10X multiplier Function Switches Front Panel High...

Page 18: ...Notes 16...

Page 19: ......

Page 20: ...Samson Technologies Corp 575 Underhill Blvd P O Box 9031 Syosset NY 11791 9031 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 516 364 3888 www samsontech com...

Reviews: