8-1
EB 20a_EN
May 2022 edition
Subject to technical changes
Malfunction
8 Malfunction
When rectifying the faults, chapter “1 Safety instructions and safety measures” must be observed.
8.1
Detecting and rectifying errors
Type of fault
Possible cause
Measures
Leaks in the pipe connection
The
fl
ange connection of the
lined ball valve is leaky
Tighten the
fl
ange screws.
An excessive tightening torque when retightening the
fl
ange screws
can damage the valve and pipe!
The permissible torque for retightening the pipe
fl
ange screws is
limited.
Retighten the
fl
ange connection with the respective tightening torque,
see Table 15-2 or Table 15-3 in Chapter “15.1.1 Tightening torques”.
If necessary, increase the tightening torque to max. 20%.
The
fl
ange connection is still
leaky after retightening
Loosen the
fl
ange connection and remove the ball valve, see chapter
“1 Safety instructions and safety measures“.
Check the plane parallelism of the
fl
ange connection and correct if it is
not suf
fi
cient.
Check the surfaces on all
fl
anges. If the plastic lining is damaged,
replace the ball valve together with its
fl
ange seals, if available.
Check the
fl
ange seals. If the seals are damaged, replace them.
Leaks in the body parts
The body section connection
loosened.
Retighten the body halves with the respective tightening torque, see
Table 15-1 in Chapter “15.1.1 Tightening torques”.
Body parts untight after
retightening
Replace the body sealing and/or valve, see chapter “1 Safety
instructions and safety measures“.
Increased medium
fl
ow rate
with the ball valve closed
Leakage in the closed position Remove and inspect the ball valve, see chapter “1 Safety instructions
and safety measures”.
The ball valve is damaged
Repairs are necessary.
Remove the ball valve, see chapter “1 Safety instructions and safety
measures”.
Request spare parts from PFEIFFER, see Chapter “15.2 Spare parts”.
For the required repair instructions, see Chapter “12 Repairs”.
Leaks in the control shaft
sealing
Medium escapes
Danger of injury due to escaping medium!
To protect operating personnel from danger, depressurise the line on
both sides of the ball valve, see Chapter
“1 Safety instructions and
safety measures”
.
Medium escapes from the
stuf
fi
ng box
Remove the ball valve, see chapter “1 Safety instructions and safety
measures”.
Disassemble the ball valve and replace the control shaft sealing.
Request spare parts from PFEIFFER, see Chapter “15.2 Spare parts”.
For the required repair instructions, see Chapter “12 Repairs”.
NOTE
DANGER
Summary of Contents for EB 20a
Page 22: ...4 4 EB 20a_EN May 2022 edition Subject to technical changes Shipment and on site transport...
Page 28: ...6 2 EB 20a_EN May 2022 edition Subject to technical changes Start up...
Page 30: ...7 2 EB 20a_EN May 2022 edition Subject to technical changes Operation...
Page 36: ...10 2 EB 20a_EN May 2022 edition Subject to technical changes Decommissioning...
Page 38: ...11 2 EB 20a_EN May 2022 edition Subject to technical changes Removal...
Page 44: ...13 2 EB 20a_EN May 2022 edition Subject to technical changes Disposal...
Page 46: ...14 2 EB 20a_EN May 2022 edition Subject to technical changes Certificates...
Page 47: ...14 3 EB 20a_EN May 2022 edition Subject to technical changes Certificates...
Page 48: ...14 4 EB 20a_EN May 2022 edition Subject to technical changes Certificates...
Page 49: ...14 5 EB 20a_EN May 2022 edition Subject to technical changes Certificates...
Page 50: ...14 6 EB 20a_EN May 2022 edition Subject to technical changes Certificates...
Page 59: ...EB 20a_EN May 2022 edition Subject to technical changes...