EB 3007 EN
5-7
Installation
ening torques (see 'Tightening torques' in
Annex).
7. Mount the control lines (to be installed on
site) and any needle valves and open
them.
– Mount the control lines (to be installed on
site) on the actuator. Observe the speci-
fied tightening torques (see 'Tightening
torques' in Annex).
– For
steam
or
liquids above 150 °C
in-
stall the compensation chamber and fill it
with the process medium. Observe the
specified tightening torques (see 'Tighten
-
ing torques' in Annex).
5.4 Testing the regulator
Risk of bursting due to incorrect opening of
pressurized equipment or components.
Regulators and pipelines are pressure equip
-
ment that may burst when handled incor
-
rectly. Flying projectile fragments or the re-
lease of process medium under pressure can
cause serious injury or even death.
Before working on the regulator:
Î
Depressurize all plant sections concerned
and the regulator.
Î
Disconnect the control line.
Î
Drain the process medium from all the
plant sections concerned as well as the
valve.
DANGER
!
Risk of personal injury due to pressurized
components and process medium being dis-
charged.
Incorrect opening of pressure equipment or
mounting parts may lead to the process me-
dium escaping to the atmosphere.
Î
Do not loosen the control line while the
valve is pressurized.
Î
Do not start up the regulator until all
parts have been mounted.
Risk of hearing loss or deafness due to loud
noise.
Noise emission (e.g. cavitation) may occur
during operation caused by the process me-
dium and the operating conditions.
Î
Wear hearing protection when working
near the valve. Follow the instructions
given by the plant operator.
Risk of burn injuries due to hot or very cold
components and pipelines.
Depending on the process medium, valve
components and pipelines may get very hot
or cold and cause burn injuries.
Î
Wear protective clothing and safety
gloves.
The regulator components are delivered by
SAMSON ready for use. To test the regulator
functioning before start-up or putting back
the regulator into operation, perform the fol-
lowing tests:
WARNING
!
WARNING
!
WARNING
!