9-2
EB 3009 EN
Servicing
The regulator was checked by SAMSON
before it left the factory.
− Certain test results certified by SAMSON
lose their validity when the regulator is
opened. Such testing includes seat leakage
and leak tests.
−
The product warranty becomes void if
service or repair work not described in
these instructions is performed without
prior agreement by SAMSON's After-sales
Service.
−
Only use original spare parts by
SAMSON, which comply with the original
specifications.
SAMSON's After-sales Service can support
you in drawing up an inspection and test
plan for your plant.
Note
Tip
1
Valve body
2
Seat
3
Plug
4
Plug stem
5
Threaded connection for diaphragm actuator
6
Actuator stem
7
Diaphragm stem
10 Actuator housing
10.1 Distance ring
11 Two diaphragms
11.1 Operating diaphragm for upstream pressure
11.2 Operating diaphragm for downstream pressure
12 Diaphragm rupture indicator
13 Set point springs
13.1 Force limiter
14
Control line 8x1 mm
15 Spacer bushing including seal
16 Housing bolts (two long bolts opposite each other,
DN 15 to 25/NPS ½ to 1 only)
16.1 Top housing bolts
16.2
Bottom housing bolts
17 Diaphragm plate nut
18 Pressure switch (optional, not shown)
19 Compensation chamber (optional)
20 Filler plug
21
Screw fitting (control line)
Summary of Contents for 42-10
Page 24: ...3 10 EB 3009 EN...
Page 54: ...8 4 EB 3009 EN...
Page 60: ...9 6 EB 3009 EN...
Page 64: ...11 2 EB 3009 EN...
Page 66: ...12 2 EB 3009 EN...
Page 68: ...13 2 EB 3009 EN...
Page 70: ...14 2 EB 3009 EN Certificates 1...
Page 71: ...EB 3009 EN 14 3 Certificates...
Page 72: ...14 4 EB 3009 EN...
Page 75: ......