5-4
EB 3756 EN
Installation
a) K
VS
1.4, 2.0, 2.9 and 4.3
Î
Loosen the cap screw on the connection
plate and remove plate 1 and turnable
gasket 2.
Î
Turn the turnable gasket 2 by 90°. The
tip of gasket 2 must rest in the plate cut-
out marked '9'.
Î
Fasten plate 1 and turnable gasket 2 to
the connection plate.
Fig. 5-2:
Turnable gasket of the booster valve
b) K
VS
10
When the control pressure at port 9 is higher
than the operating pressure at port 1, a
check valve in these devices automatically
switches the pilot supply from internal to ex-
ternal.
c) K
VS
1.4
Type 3756-1
Î
Undo the two hexagonal socket head
screws (Fig. 5-3) and carefully remove
the CNOMO interface.
Fig. 5-3:
CNOMO interface with booster
Make sure that the gaskets on the booster
valve and CNOMO interface do not get
damaged.
Fig. 5-4:
CNOMO interface and booster