background image

6

 

 

T 8313 EN

Mounting types

There are two types of mounting depending on the valve/actuator combination: mounting using a crossbeam or mounting on rods.
When the actuator is mounted to the valve using a crossbeam (Form B, Fig. 8), the actuator is fastened to the valve bonnet using a 
central nut.
When the actuator is mounted on rods (Form C, Fig. 9) the actuator is connected to the valve bonnet using rods. In this case, a 
crossbeam is not required for mounting the actuator.

Table 2: 

Mounting types (see Fig. 8 and Fig. 9)

Version

Integrated i/p 

converter

Type 3725 Positioner (direct attachment)

Actuator area

120 cm²

120 cm²

350 cm²

Travel

15 mm

15 mm

15 mm

30 mm

Type ... Valve

Nominal size DN

3321

15 to 50

Form B

Form B

3321

65 to 100

Form C

Form C

3321

100

Form C

3323

15 to 50

Form B

Form B

3323

65 to 80

Form C

Form C

3323

100

Form C

3531

15 to 80

Form B

Form B

3535

15 to 80

Form B

Form B

3214

65 to 100

Form B

Form B

3214

125 to 250

On request

3260

65 to 80

Form B

Form B

3260

100 to 150

On request

Fig. 8: 

Form B: mounting using crossbeam

Fig. 9: 

Form C: mounting on rods

Summary of Contents for 3372

Page 1: ...aphragm cases a rolling diaphragm and internal springs The Type 3372 Electropneumatic Actua tor is controlled by a 4 to 20 mA signal For throttling service an i p converter is integrated into the actu...

Page 2: ...ator stem 8 8 Plug connector 14 Zero adjuster 8 2 Rod type yoke 8 9 Cover plate span and tight closing function 15 Force switch 8 3 Actuator springs 10 i p converter 16 Rod nut 8 4 Rolling diaphragm 1...

Page 3: ...41 7 33 60 54 2 61 Fig 7 Type 3372 Electropneumatic Actuator with 350 cm actuator area for the direct attachment of a Type 3725 Positioner Legend for Fig 6 and Fig 7 1 2 Diaphragm case 20 Hexagon bol...

Page 4: ...Switching accuracy 0 14 mA Air consumption in steady state When w 100 6 bar 200 ln h 4 bar 160 ln h 100 ln h with a supply pressure up to 6 bar and a signal pressure of 0 6 bar Air output capacity To...

Page 5: ...on Stem retracts Stem retracts Stem extends Stem extends Stem retracts Stem retracts Stem extends Stem extends Stem retracts Stem extends Stem retracts Stem extends Bench range 0 4 to 1 4 1 4 to 2 3 2...

Page 6: ...t required for mounting the actuator Table 2 Mounting types see Fig 8 and Fig 9 Version Integrated i p converter Type 3725 Positioner direct attachment Actuator area 120 cm 120 cm 350 cm Travel 15 mm...

Page 7: ...bar of 2 3 4 5 6 120 15 1800 0 4 to 1 4 4 0 5 1 7 0 7 1 9 3 1 1800 1 4 to 2 3 8 1 7 2 8 0 8 2 3 2 4 4 1800 2 1 to 3 3 12 2 5 4 0 350 5250 1 5 to 2 1 8 3 15 6 65 6 65 6 65 5250 2 1 to 2 7 6 7 35 9 5 30...

Page 8: ...22 English Order specifications Electropneumatic actuator Type 3372 Version With integrated i p converter With Type 3725 Positioner direct attachment Attachment to the valve Type Mounting type Accord...

Reviews: