EB 8026 EN
37
Servicing
2. Unthread the stem connector nut (9) and
lock nut (10) from the plug stem exten-
sion (25).
3. Unscrew the threaded bushing (8).
4. Remove nuts (33) and bolts (32).
5.
Carefully lift the flange (2) over the plug
stem extension (25).
6. Pull all the packing parts out of the pack-
ing chamber using a suitable tool.
7. Renew the damaged parts and carefully
clean the packing chamber.
8.
Apply a suitable lubricant to all the pack-
ing parts and to the plug stem extension
(25).
9.
Carefully place the flange (2) over the
plug stem extension (25) onto the insulat-
ing section (21).
Mixing valve with V-port plug:
place the
flange (2) onto the insulating section,
making sure that the largest V-shaped
port of the V-port plug faces toward the
valve outlet (
AB
) at the side. See sec-
tion 5.1.
16
8
12
16
15.2
15
15.1
11
2
Flange
5
Plug with plug stem
8
Threaded bushing (packing nut)
11
Spring
12 Washer
15 Packing
15.1
Shim with retaining ring
15.2 Seals
16 Packing rings
16
8
12
11
2
5
Fig. 8:
Standard packing (left) and ADSEAL packing (right)
Summary of Contents for 3244
Page 11: ...EB 8026 EN 11...
Page 31: ...EB 8026 EN 31...
Page 48: ...48 EB 8026 EN...
Page 50: ...50 EB 8026 EN 81 25 84 83 82 80 32 2 11 12 16 8 10 9 15 7 39 30 33 14 21 23 81 26...