20 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 21
cAteGoRY
PARAMeteR
SPeciFicAtion
AC INPUT
Input Voltage
230 VAC Nominal (+6% / -10%), 50/60 Hz
Input Current
2.75A @ 120 VAC
Input Current at No Load
105 mA ± 10%
Inrush current at Startup
32A ±5% for 2.4 ms
DC oUTPUT
Output Voltage at Load Terminals
13.8VDC ± 0.2V
Output Voltage at Battery
Terminals (Without battery)
13.8VDC ± 0.2V
Output Voltage at Battery
Terminals (With battery)
Actual battery voltage corresponding to
State of Charge; 13.5V ± 0.2V when battery is
fully charged and floating
Output Voltage Noise and Ripple
< 150 mV Peak to Peak
Continuous Output Current at
Load Terminals
19A (With battery backup);
23A (Without battery backup)
Continuous Output Current at
Battery Terminals (Battery Backup)
Up to 4A (When battery is completely discharged
to Standing Voltage of 11.1V)
Output Current Limit at Load
Terminals
- 25A for 100 sec (External 25A fuse will blow)
- Surge > 25A as permitted by Time Current
Characteristics of 25A load side fuse (In Battery
backup Mode)
Output Current Limit at Battery
Terminals (Battery Backup)
4A (When battery is completely discharged to
Standing Voltage of 11.4V)
Peak Efficiency
85% ± 5%
ExTErNAL
BACKUP BATTErY
Type & Voltage
Lead Acid, 12V
Capacity
40Ah to 100 Ah
ProTECTIoNS
Short Circuit, Overload
External 25A Fuse will blow
Over Voltage
Regulated by PWM Controller
Over Temperature
(Power Supply Section)
Output of Power Supply Section shuts down when
Power Transformer winding temperature ≥ 105°C
± 5°C / 221°F ± 9°F); Auto reset on cooling down
to ≤ 75°C ± 5°C / 167°F ± 9°F
CooLING
Forced Air
Temperature controlled fan. ON when Power
Transformer winding temperature is ≥ 60°C ± 5°C
/ 140°F ± 9°F; OFF when cools down to ≤ 40°C ±
5°C / 104°F ± 9°F
fUSES
Internal AC Side Fuse
- 5 mm x 20 mm Glass Fuse
- 250V, 4A, Time Delay Type
- Bussmann: “GDC-4”; LittelFuse - “218004”
External Battery Side Fuse (By User) - 32V, 25 A, Fast Acting
- Within 7” of the Battery Positive Post
External Load Side Fuse (By User)
- 32V, 25 A, Fast Acting
- Within 7” from Load Terminal of the unit
SeCtIOn 9 |