SamplexPower PSE-12100A Owner'S Manual Download Page 7

Battery Current & Voltage Bar Graph Meters (

GREEN, YELLOW, RED

).

d. Current Indicator. 

This illuminated Bar Graph monitors the current

being drawn from the battery by the inverter. Depending on the amount of
current being drawn, the Bar Graph reading generally will be in the GREEN
or YELLOW zone. When the reading rises to the RED zone, the inverter
may automatically shut down. In this event it is likely that the draw of the
equipment or appliance being operated is greater than the battery is
capable of producing.

Voltage Indicator. 

This Bar Graph indicates the DC voltage available at

the input terminals of the inverter. This voltage will be lower than the voltage
at the battery terminals by an amount equal to the voltage drop along the
input cables and connectors. This drop is equal to the product of the input
current and the resistance of the cables and the connectors. When the
output power is low, the input current will be low and the drop will also be
low. The input voltage at the inverter will thus be almost equal to the battery
voltage. At higher output loads, the input current will be higher and the drop
will also be higher, in this case, the input voltage at the inverter will be lower
than the battery voltage.

The inverter is designed to operate with input voltages ranging from 10 to 15
volts of direct current (DC). When the voltage drops below 10.5 volts DC,
the voltage indicator will register in the lower RED zone and an audible
alarm will sound. If the voltage drops below 10 volts DC, the voltage
indicator will go out and the inverter will automatically shut down.

The inverter will also shut down automatically when the input voltage
exceeds 15 volts DC.

Despite this “built in” protection the inverter may be damaged if the input
voltage exceeds 15 volts DC and damage caused by excess voltage input is
not covered under the warranty. Under optimum conditions, the voltage
reading will be in the GREEN zone.

Note:
In the event of automatic shut down or continuous audible alarm, turn the
inverter OFF (O) until the source of the related problem has been deter-
mined and resolved.

e.

Two Standard North American NEMA 5-15R Receptacles 

are

provided on models PSE-12100A and PSE-12150A. On PSE-12250A, the
output is available from unconnected, Live (BLACK), Neutral (WHITE) and
Earth ground (GREEN) wires for connection to an external breaker panel. A
plate with standard North American NEMA 5-15 receptacles(e) wired in
series with a 15 A circuit breaker (j) is provided as an accessory. Use this
receptacle if you require power to be drawn from the front panel. (This will
require connection). As this receptacle(e) is fed through a 15A breaker (j),
the power drawn from here should be limited to 1500 watts.

Page 6

Summary of Contents for PSE-12100A

Page 1: ...Owner s Manual Please read this manual before operating your Inverter DC AC Inverters PSE 12100A PSE 12150A PSE 12250A ...

Page 2: ...ing proper Wire Cable Sizes 8 Installation Operation 9 Appliances that may not operate correctly on modified sinewave 11 Powering Television Audio Equipment 11 Powering Microwave Ovens 12 Technical Information 12 Installation Locations 13 Review 14 Specifications 15 Troubleshooting Guide 16 17 Notes 18 INDEX Page 1 ...

Page 3: ...hen the battery is being charged simultaneously the output voltage of the charging device will be fed to the inverter Ensure that the charging voltage of the alternator has not been set above 15V Do not use an unregulated solar panel It s voltage can reach up to 18V on a very cold day When using a regulated solar panel it s voltage should not be set beyond 15V Do not connect to a 24V Battery Ensur...

Page 4: ...designed to operate equipment and appliances with start up load wattage ratings no higher than its own maximum continu ous wattage rating For example the PSE 12150A model has a maximum continuous rating of 1500 watts Although this model has the capacity to briefly provide up to 3000 watts of surge power that is excess current it is designed to operate equipment and appliances with start up load re...

Page 5: ...f LAYOUT PSE 12100A PSE 12150A PSE 12250A Rear View Bottom View a c d e b g h i Front View b a c d e k j f g h i Rear View Page 4 ...

Page 6: ...f excess temperature the High Speed Cooling Fan also will automatically turn on Overheating may result when the inverter is being operated at levels exceeding its wattage rating or because it has been placed in a location or in a manner which prevents proper heat dissipation After approximately 15 minutes the High Tempera ture Indicator light and the Cooling Fan will turn off and the inverter will...

Page 7: ...erate with input voltages ranging from 10 to 15 volts of direct current DC When the voltage drops below 10 5 volts DC the voltage indicator will register in the lower RED zone and an audible alarm will sound If the voltage drops below 10 volts DC the voltage indicator will go out and the inverter will automatically shut down The inverter will also shut down automatically when the input voltage exc...

Page 8: ... when the internal temperature exceeds design parameters for safe operation The Cooling Fan will automatically turn off when the temperature drops to a safe operating level This fan does not run continuously h Power Input Terminals WHITE Negative RED Positive i Chassis Ground Terminal Lug j Circuit Breaker This is provided for PSE 12250A k Punched Holes These holes are provided for entry of cables...

Page 9: ...required to be delivered by the battery 2500 Watts divided by 10 250 Amps AH required to be delivered by the battery 250 Amps x 2 Hours 500 AH Hence the AH capacity of the battery should be more than 500 AH or 500 divided by 0 3 1666 RC Use 3 Type 8D 12 V batteries in parallel to get 600 AH capacity Note The AH capacity can be increased by connecting 2 or more batteries in parallel For example if ...

Page 10: ...A models BLACK on the PSE 12250A model on the inverter to the Negative terminal on the 12 volt power source Make certain the connection is secure 4 Confirm that the wire you have just installed is properly connected Specifically make certain that the wire is connected to the Negative terminals on both the inverter and the 12 volt power source 5 Connect the wire from the Positive terminal RED on al...

Page 11: ... or appliance to be operated is turned off Plug the equipment or appliance into one of the two AC receptacles on the front panel of the inverter 10 Turn the inverter on Turn the equipment or appliance on Note The use of an extension cord from the inverter to the appliance or equipment being operated will not significantly decrease the power being generated by the inverter For best operating result...

Page 12: ... Although the inverter is shielded and filtered to minimize signal interference some interference with your television picture may be unavoidable especially with weak signals However here are some suggestions that may improve the reception 1 First make certain that the television antenna produces a clear signal under normal operating conditions i e at home plugged into a standard 117 AC wall outle...

Page 13: ...FET transistors The output waveform resulting from this conversion is a quasi sine wave or a modified sine wave as shown below This stepped waveform is nearly similar to the sinewave power generated by utilities and has a broad range of applications The modified sine wave produced by inverters has a root mean square RMS voltage of 110 to 120 volts The majority of AC voltmeters are not calibrated t...

Page 14: ... wet Water and many other liquids can conduct electricity which may lead to serious injury or death HEAT The ambient air temperature should be between 50o and 80o F Avoid placing the inverter on or near heating vents radiators or other sources of heat Do not place the inverter in direct sunlight VENTILATION In order to properly disperse heat generated while the inverter is in operation keep it wel...

Page 15: ...he rated power consumption of the equipment is in the range of the rated capacity of the inverter test the inverter to ensure that it will operate properly When attempting to recharge battery chargers monitor the temperature of the battery charger for approximately 10 minutes If the battery charger becomes abnormally warm disconnect it from the inverter immediately When operating the inverter with...

Page 16: ...D RED LED FOR OVERTEMP Input side DC Fuses Automotive Type ATC 32V ENVIRONMENT CONDITIONS Operating Temp deg C Storage Temp deg C Relative Humidity OUTPUT CONNECTORS Wires for connection to external distribution panel Receptacle NEMA 5 15R Dimensions W x D x H mm Weight Kg PSE 12100A 10 15V 125A 117 5 10 60Hz 1000W 2000W Modified Sine Wave 0 35A 85 to 90 PSE 12150A 10 15V 200A 117 5 10 60Hz 1500W ...

Page 17: ...se true RMS reading meter See Page 12 Technical Information Automatic Shutdown due to input voltage beyond 15V this may permanently damage the inverter Inverter connected to 24V battery Ensure battery is 12V instead of 12V Charging alternator s voltage has been set Set the voltage correctly or repair beyond 15V or its regulator has become defective Batteries are being charged simultaneously Discon...

Page 18: ...n long Use lower gauge wire See battery cables which cause excessive Page 8 Wire Cable Sizes section of voltage drop this manual Keep wire length as short as possible PROBLEM TV Interference REASON POSSIBLE SOLUTION Electrical interference from inverter Add a Ferrite data line filter onto the TV power or See Page 11 Television and Audio Equipment section of this manual TROUBLESHOOTING GUIDE Page 1...

Page 19: ..._______________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ _________________...

Page 20: ...110 17 Fawcett Rd Coquitlam B C Canada V3K 6V2 T 604 525 3836 F 604 525 5221 e mail samlex samlexamerica com website www samlexamerica com ...

Reviews: