
PLEASE TAKE THE FOLLOWING PRECAUTIONS.
FAILURE TO ABIDE BY THESE REQUIREMENTS
WILL VOID THE WARRANTY.
Never parallel the 115V AC output of the inverter with the
output from a generator or electric mains. This will instantly
burn the inverter.
Although this inverter has an input OVER VOLTAGE SHUT
DOWN at 15V, input voltages higher than 15V will cause
permanent damage. Ensure the following when the battery is
being charged simultaneously (the output voltage of the
charging device will be fed to the inverter):
Ensure that the charging voltage of the alternator has not been set above
15V.
Do not use an unregulated solar panel. It's voltage can reach up to 18V on
a very cold day. When using a regulated solar panel, it's voltage should not
be set beyond 15V.
Do not connect to a 24V Battery .
Ensure that the voltage of the battery charger does not exceed 15V in any
condition.
DO NOT REVERSE THE POLARITY OF THE INPUT CONNECTIONS.
THIS WILL PERMANENTLY DAMAGE THE INVERTER.
WARNING
Page 2