We Larius S.r.l.
Via Stoppani, 21
23801 Calolziocorte (LC)
declare under our sole responsability that the product:
NOVA series pneumatic piston transfer pump.
to which this declaration relates complies with the following
directives:
- Directive 94/9/EC (ATEX)
The conformity are under observance of the following standards
3
X
or standards documents:
- EN 1127-1 - EN 13463-5
- EN 13463-1
Markings
II 2 G c IIB T6 Tamb.: - 20°C ÷ 60°C
Tmax. fluid: 60°
C
Tech. File:
NOVA/ATX/08
Technical dossier kept on file c/o:
INERIS (0080
)
Calolziocorte- LC, 15/12/2008
Signature
(LARIUS)
Read the indications provided in the user and
maintenance manual carefully prior to installa-
tion. All of the maintenance operations must be
performed according to the indications provided
in the manual.
NOVA series pneumatic piston transfer pump
cannot work without material.
All of the installation and maintenance operations
must be performed by qualified personnel.
• The grounding wire for the pumps indicated above
must be grounded using an appropriate anti-loosening
connection.
• The tubes used to connect the delivery and suction
lines must be either metallic, plastic with metallic
braid, or plastic with fabric braid and a suitable
grounding conductor.
• The pumps must be installed on properly grounded
metallic or antistatic drums.
• The gases or vapours of any flammable liquids present
must belong to group IIB.
• Based on the type of use and the substances employed,
the user must periodically check for any encrustations
and must verify the cleanliness, the wear status and
the correct functionality of the pump on a regular
basis.
• The user must periodically clean the suction filter in
order to prevent any solid materials from entering
the pump. The air used to power the pump must be
filtered and must come from a SAFE AREA.
SAFETY INSTRUCTIONS FOR INSTALLATION IN HAZARDOUS AREAS
NOVA 10:1
36
ED.
01 - 09/2023 - Cod. 150209