SETTING-UP
CONNECTON OF THE PRODUCT FEEDING HOSE
Connect the gun hose (
I5
) to the coupling (
I6
).
CONNECTION OF THE PRODUCT HOSE
Connect the product suction hose (
I3
) to the pump coupling (
I4
).
CONNECTION OF THE SPRAYING GUN
Connect the spraying gun (
I7
) to the prodcut feeding hose (I
8
).
PUMP FASTENING ON THE HOIST
For the correct fastening of the pump on the hoist, follow the
procedure described in the manual for use and maintenance
of the air hoist.
CONNECTION TO THE FEED AIR
For pump feed use a hose with an internal diameter higher
than 20 mm.
Install at the pump inlet an air pressure regula-
tor
(it is suggested complete with condensate
filter and lubricator)
. The outlet pressure of the
material is 45 times (SUPER NOVA 45:1) or 68
times (SUPER NOVA 68:1) or 80 times (SUPER NOVA 80:1) the
inlet pressure of the pump feed air. Therefore, it is extremely
important to adjust the value of the feed air pressure.
CONNECTION OF THE RECIRCULATION HOSE
Connect the recirculation hose (
I1
) to the coupling (
I2)
.
*
TYPICAL INSTALLATION
The
SUPER NOVA p
ump is generally supplied on support for
wall fastening or on trolley or on air host.
For the correct fastening of the pump on other structures use
the 4 holes placed at the base of the pneumatic motor
(see the
illustration for dimensions)
.
*Int. holes