7

MINIPEGASO

ED. 05 - 09/2020 - Cod. 150168

SETTING-UP

CONNECTION OF THE FLEXIBLE HOSE TO THE GUN

•  Connect the flexible hose

 (

H1

to the gun air pressure gauge 

coupling

 (

H2

)

 of the pump

 

•  Connect the flexible hose

 (

H1

to the gun coupling

 (

H3

).

•  Connect the flexible product delivery hose (H4) to the delivery 

coupling 

(

H5

of the pump. Tighten the metal clamp

 (

H6

).

H2

H1

H1

H3

H4

H5

H6

FOR  CONNECTION BETWEEN PUMP, FLEXIBLE HOSE AND 
SPRAY GUN BEFORE USING THE EQUIPMENT.       

•   ALWAYS USE THE FLExIBLE HOSE SUPPLIED WITH STAN

-

DARD KIT. 

•   THE USE OF ANY ACCESSORIES OR TOOLING OTHER THAN 

THOSE RECOMMENDED IN THIS MANUAL, MAY CAUSE 
DAMAGE OR INJURE THE OPERATOR.

•   THE FLUID CONTAINED IN THE FLExIBLE HOSE CAN BE VERY 

DANGEROUS. HANDLE THE FLEXIBLE HOSE CAREFULLY. DO 
NOT PULL THE FLEXIBLE HOSE TO MOVE THE EQUIPMENT. 
NEVER USE A DAMAGED OR A REPAIRED FLEXIBLE HOSE.

The high speed of travel of the product in the hose 

can create static electricity through discharges 

and sparks. It is suggested to earth the equipment. 

The pump is earthed through the earth cable of 

the supply. 

The gun is earthed through the high pressure 

flexible hose.  

All the conductors near the work area must be 

earthed.

Never spray over flammable products or solvents 
in closed places.

Never use the tooling in presence of potentially 
explosive gas.

Always check that the product is compatible with 
the materials composing the equipment (

pump, 

spray gun, flexible hose and accessories

) with 

which it can come into contact. Never use paints 
or solvents containing Halogen Hydrocarbons 
(

as the Methylene Chloride

). If these products 

come into contact with aluminium parts can 
provoke dangerous chemical reactions with risk 
of corrosion and explosion.

If the product to be used is toxic, avoid inhalation 
and contact by using protection gloves, goggles 
and proper face shields.

Take proper safety measures for the protection 
of hearing in case of work near the plant.

Avoid approaching too much to the pump piston 
rod when the pump is working or under pressure. 
A sudden movement of the piston rod can cause 
wounds or finger squashing.

H

Fig. 1H

Fig. 2H

Fig. 3H

Summary of Contents for LARIUS MINIPEGASO

Page 1: ...w w w l a r i u s c o m ED 05 09 2020 Manuale Cod 150168 MINIPEGASO Pneumatic double Diaphragm pump II 2 G c IIB T4 OPERATING AND MAINTENANCE MANUAL EN...

Page 2: ...manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconv...

Page 3: ...l receive a range of support services enabling you to achieve the results desired quickly and professionally INDEX WARNING 2 WORKING PRINCIPLE 3 TECHNICAL DATA 4 DESCRIPTION OF THE EQUIPMENT 5 TRANSPO...

Page 4: ...nt carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not...

Page 5: ...replace in just a few minutes without having to use any tools large material hopper of 50 litrecapacity removablefromthecarriagewithouthaving to use any tools Funnel shaped hopper facilitates the fill...

Page 6: ...fluid pressure 7 bar Maximum air pressure 7 bar Acoustic level Max 50 db A Tank capacity 50 l Gunes Max air pressure max fluido pressure set of nozzles Turbo gun 8 bar 116 psi 20 bar 290 psi 3 4 6 8 1...

Page 7: ...11 12 8 5 4 3 12 11 6 7 Pos Description 1 Trolley 2 Air pressure gauge for pump 3 Manometer low pressure 4 Air intake for pump feed 5 Gun air pressure gauge 6 Product delivery valve Pos Description 7...

Page 8: ...UT THE USE OF SAFETY DEVICES FOR THEIR OWN SAFETY AND ABOUTTHEGENERALRULESFORACCIDENTPREVENTION INCOMPLIANCEWITHINTERNATIONALREGULATIONSAND WITH THE LAWS OF THE COUNTRY WHERE THE PLANT IS USED THE BEH...

Page 9: ...estedtoearththeequipment The pump is earthed through the earth cable of the supply The gun is earthed through the high pressure flexible hose All the conductors near the work area must be earthed Neve...

Page 10: ...e trigger down in order to expel the oil contained until clean liquid flows out Now release the trigger Aim the gun against the cleaning liquid bucket and pull the trigger to recover the left over sol...

Page 11: ...duct delivery valve H14 on the gun and open the recirculation valve H15 Turn the pressure adjustment knob H11 clockwise to start the pump If the product has properly been mixed you should see it come...

Page 12: ...essure I6 until reaching the necessary operating conditions I1 I2 I4 I3 I5 I6 I Beforestartingthepump itisimportanttosend a small amount of atomization air to the gun Fig 1I Holdthecock I1 slightlyope...

Page 13: ...e J2 Place the recirculation hose back into the tank Slowly start the pump Turn the pressure adjustment knob J3 clockwise to start the pump Spray into a receptacle to clean the hose H5 and the gun J6...

Page 14: ...ecommend you to suck and to leave light mineral oil inside the pumping group and the flexible hose If necessary change the cleaning liquid and repeat the operation several times until all the product...

Page 15: ...e intake filter Clean The membrane has ruptured Replace the membrane The drive valve has locked Press the reset buttons located at the sides of the valve The pump operates at accelerated speed and doe...

Page 16: ...I n t e n t i o n a l l y b l a n k p a g e...

Page 17: ...rius com 15 MINIPEGASO ED 05 09 2020 Cod 150168 SPARE PARTS Control unit page 21 Complete hydraulic body page 18 Frame unit page 20 Delivey unit page 20 Turbo gun unit pag 22 Tex gun unit pag 24 L M N...

Page 18: ...BODY WARNING Always indicate code and quantity for each part required 5 6 7 2 5 7 6 29 28 27 26 18 19 8 9 10 11 34 31 30 12 15 16 13 17 15 14 12 20 21 21 21 21 21 24 24 24 24 25 26 27 22 22 22 22 22 2...

Page 19: ...8402 O Ring 4 17 8409 8409 Insert for machine body 1 18 8363 8363 Gasket 1 19 8364 8364 Piston 1 20 8365 8365 Piston rod 1 21 8362 8362 Washer 5 22 96840 96840 O Ring 5 23 4026 4026 O Ring 5 24 8361...

Page 20: ...m 18 MINIPEGASO ED 05 09 2020 Cod 150168 1 5 14 15 15 14 6 14 15 16 16 4 3 15 14 16 7 8 9 11 10 16 2 12 17 18 18 13 12 FRAME UNIT rEf 20850 WARNING Always indicate code and quantity for each part requ...

Page 21: ...SS4 3 37238 Wheel 2 4 91047 Flexible washers 4 5 84007 Split pin 2 6 30530 Support plate l4 1 7 18249 1 Cover tank 1 8 18249 Tank 50 l 1 9 18246 Support rack 1 10 20833 Elbow F F 1 11 20807 Hose tail...

Page 22: ...20810 Reduction M M 2 4 20812 Tap F F 2 5 8071 Washer 2 Pos Code Description Q ty 6 20809 Fitting 2 7 30553 Tightening clamp 3 8 20835 Delivery hose 10mt 9 20811 Union a L M F 1 10 30528 Recirculatio...

Page 23: ...or 1 6 54003 Washer 4 7 8037 Screw 4 8 8042 Self braking nut 4 Pos Code Description Q ty 9 96259 Manometer 1 10 8167 Gun pressure gauge 1 11 3354 Union M M 2 12 8063 Union M F 2 13 3358 Union T FFF 1...

Page 24: ...05 09 2020 Cod 150168 25 26 27 24 4 5 6 7 8 10 11 9 12 13 14 15 17 16 18 25 1 27 28 19 20 21 22 23 32 33 32 35 2 24 29 30 31 3 32 34 TURBO GUN UNIT RIF 21050 WARNING Always indicate code and quantity...

Page 25: ...16 21083 Air rod spring 1 17 96279 O Ring 115 1 18 21065 Air spring plug 1 Pos Code Description Q ty 19 21066 Air open ring nut 1 20 18755 O Ring 106 1 21 21067 Guide for air spring 1 22 21084 Materi...

Page 26: ...Description Q ty 14400 Complete gun without tip 1 30525 Attack for material pipe 1 2 3563 Nipple 1 3 4004 Ball valve 1 4 9902 Check valve 1 5 5313 Fitting 1 TEX GUN UNIT RIF 30567 2 3 4 5 1 WARNING Al...

Page 27: ...CLEAN WITH NOZZLE Art Description 11421 130 cm 11426 180 cm 11431 240 cm MX Art Description 217550 MX 750 217560 MX 1000 E 217570 MX 1100 E TELESCOPIC PAINT ROLLER Art Description 16988 Roller cover...

Page 28: ...gas fog and vapour c Manufacturing safety c T4 Class of temperature T5 10 C 50 C Environment temperature 60 C Maximum fluid temperature xxxxx AA Serial number xxxxx PROGRESSIVE year AA DANGEROUS AREA...

Page 29: ...eaning thewearingandthecorrectpump sfunctioning It is advisable that a filter will be placed at the suction of the material to prevent solid parts entering the pump The pipes used to connect suction a...

Page 30: ...www larius com 28 MINIPEGASO ED 05 09 2020 Cod 150168...

Page 31: ...ty that the product Company Signature Calolziocorte 15 September 2020 Location Date complies with the directives EC Directive 2006 42 Machinery Directive furthermore to the harmonized standards UNI EN...

Page 32: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...

Reviews: