MAINTENANCE
CLEANING AFTER SPRAY PAINTING OR A PRODUCT CHANGE
• Introduce water into the pump tank.
• Close the delivery valve
(
J1
)
and open the recirculation valve
(
J2
).
•
Insert the recirculation hose (
J4
) in the product collection
receptacle.
• Slowly start the pump until all the liquid in the tank and the
pump has drained out.
Repeat this operation several times until complete cleaning.
• Close the recirculation valve
(
J1
)
and open the delivery valve
(
J2
).
• Place the recirculation hose back into the tank.
• Slowly start the pump.
• Turn the pressure adjustment knob
(
J3
)
clockwise to start
the pump.
•
Spray into a receptacle to clean the hose (
H5
) and the gun
(
J6
). Repeat this operation several times until complete
cleaning.
Open
Close
Open
Close
J1
J2
J3
J4
J1
J2
J
Before cleaning the pump it is important to send
a small amount of atomization air to the gun.
Hold the cock slightly open, thus preventing
the product from returning to the atomization
air delivery circuit and clogging the gun and
the air delivery hose.
Insert the block to allow the air to escape
when filling the delivery hose with product for
the first time.
Fig. 1J
Fig. 2J
Fig. 3J
Fig. 4J