JOLLY
www.larius.com
9
REV.
01 - 09/2020 - Cod. 150165
H
Make sure that the electrical system is earthed
and complies with regulations.
Should anyone use an extension cable between
the unit and the socket, it must have the same
characteristics as the cable supplied
(minimum
diameter of the wire 2.5 mm
2
)
with a maximum
length of 50 mt. Higher lengths and lower dia-
meters can cause excessive voltage falls and a
bad operation of the equipment.
•
Check the mains voltage corresponds to 230 Vac - 50Hz.
•
The supply electric cable (
H4
) of the equipment is provided
without the plug. Use a plug which guarantees the plant
earthing. Only a technician or a skilled person should perform
the connection of the plug to the electric cable.
Check on power supply
PIPE CONNECTION
Connecting the flexible hose to the gun
• Connect the high pressure flexible hose (
H1
) to the pump
(
H2
) and to the gun (
H3
) ensuring to tighten the fittings (the
use of two wrenches is suggested).
NEVER use sealants on fittings’ threads.
It is ADVISED to mount a high pressure manometer at the
pump outlet (see on page “Accessories”) to read the product
pressure.
• It is recommended to use the hose provided with the standard
kit (
ref. 18036
).
NEVER use a damaged or a repaired flexible hose.
H4
Fig. 1H
Fig. 2H
Fig. 3H
H1
H2
H3