DESCRIPTION
Compressed air powered reciprocating piston pump. This high flow
capacity pump is compatible with mineral and synthetic oils and suitable
for large installations with long length piping supplying several fluid
outlets simultaneously.
This pump can be mounted on the wall, with wall mounting bracket
(Part. No. 360132), or directly on a drum or tank, using a suction tube
of a suitable length.
INSTALLATION
These pumps can be installed directly on a drum or tank. However, we
recommend installation with a wall-mounting bracket (360132).
They can be installed in three different ways:
a.
Wall mounting (360132). Mount the wall bracket to the wall
securely. Insert the pump through the wall bracket and attach it with
screws (Fig. 1).
b.
Direct drum or tank mounting. Screw the proper suction tube
(see Fig. 2) to the foot valve of the pump. Insert the tube through the
drum/tank cover. Secure the pump to the cover with M10 screws
(4 holes @ 112 mm center hole pattern diameter).
c.
Adjustable drum or tank mounting, using bung adapter. Screw the
proper suction tube (see Fig. 3) to the foot valve of the pump. Screw
the nut of the bung adapter to the 2" opening of the cover. Insert
the suction tube through the nut and secure it with the star nut at
the desired height.
In those cases in which it is required to comply with ATEX conditions, be
sure to ground the pump with the cable equipped with a clamp (534907).
These pumps are intended to be installed directly on 200 liters drums,
by fixing them to the drum cover using four M10 screws.
Fig. 3
SUCTION TUBE
PUMP
DRUM
TANK
536030
539012
368112
536031
539011
539041
B
A
Fig. 1
OPERATION
This pump is self–priming. To prime it the first time, you must connect the air supply to the pump and slowly increase the air pressure from 0 to
the desired pressure using a pressure regulator.
The pump starts to pump when an outlet valve is opened, for example an oil control gun.
360132