The U·vision
+
can be paired with a U·meter
+
, U·valve or
U·count device.
Press Power button (Fig. 1) during a short time. In the left
bottom part of the screen, you will see the current
U·vision
+
firmware version.
Fig. 1
Fig. 2
001
CONNECTING...
U vision
+
SAMOA
FW 1.04
Then the U·vision
+
will try to connect and will show the
connecting screen (Fig. 2). This screen will disappear after
a few seconds if the U·vision
+
has already been configured,
but if it has not been paired then the message will stay on
screen waiting for configuration.
BUTTONS FUNCTIONS
CONFIGURATION
1. Starting from the connecting screen (Fig. 2) press the
Power and Back button at the same time button until
U·vision
+
shows “SETUP” (Fig. 3) on the screen. Release
the buttons.
2. Then, the configuration screen is shown automatically
(Fig. 4). The U·vision
+
is now waiting for you to enter the
reel number you wish to associate.
3. To select the reel you can use the Up and Down buttons,
and press the Power button when the hose reel number
is correct.
4. Once the reel number has been set, the display shows that
the configuration has been accepted and the gun restarts
(Fig. 5). Depending on U·track configuration, the screen
will show “Normal Mode” or “Updating Work Orders”.
Fig. 3
Fig. 4
Fig. 5
Fig. 6
NOTE:
make sure that the U·meter
+
, U·valve or U·count device is powered on before pairing the U·Vision
+
.
Follow the below instructions to pair your U·Vision
+
:
001
READY!
✓
PRODUCT
001
001
001
OK!
RESTARTING...
HOSE NB.:
SETUP
?
[ 1]
Back/Cancel
Power/Select
Navigation keys (Up/Down)
Navigation keys (Left/Right)
PAIRING THE U·VISION
+
WITH A FLUID MANAGEMENT DEVICE