48 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 49
Section 12 |
Specifications
MODEL NO.
PST-2000-12
PST-2000-24
OUTPUT
OUTPUT VOLTAGE
120 VAC ± 3%
120 VAC ± 3%
MAXIMUM OUTPUT CURRENT
16.7A
16.7A
OUTPUT FREQUENCY
60 Hz ± 1%
60 Hz ± 1%
TYPE OF OUTPUT WAVEFORM
Pure Sine Wave
Pure Sine Wave
TOTAL HARMONIC DISTORTION
Of OUTPUT WAVEfORM
< 3%
< 3%
CONTINUOUS OUTPUT POWER
(At Power factor = 1)
2000 Watts
2000 Watts
SURGE OUTPUT POWER
3500 Watts (< 8 ms)
3500 Watts (< 8 ms)
PEAK EFFICIENCY
> 85%
> 85%
AC OUTPUT CONNECTIONS
(i) NEMA5-20R GFCI Duplex Receptacle (ii) Terminal block for hardwiring:
Hole
diameter
(4 mm / 0.16") and
Set Screw
(#6 x 40TPI or M3.5 x 0.6 mm Pitch)
INPUT
NOMINAL DC INPUT VOLTAGE
12V
24V
DC INPUT VOLTAGE RANGE
10.7 - 16.5 VDC
21.4 - 33 VDC
MAXIMUM INPUT CURRENT
240A
120A
DC INPUT CURRENT AT NO LOAD
< 1.0A
< 0.8A
DC INPUT CONNECTIONS
Bolt and nut : 5/16" x 18TPI
DC INPUT FUSES (INTERNAL)
6 x 40A = 240A (Each 40A, 32V,
Automotive, Blade Type)
6 x 20A = 120A (Each 20A, 32V,
Automotive, Blade Type)
DISPLAY
LED
Power, Overload, Over Temperature
Power, Overload, Over Temperature
PROTECTIONS
LOW DC INPUT VOLTAGE ALARM
10.7V ± 0.1V
21.4V ± 0.2V
LOW DC INPUT VOLTAGE SHUTDOWN
10V ± 0.1V ; Auto-reset: 11.5V ± 0.3V
20V ± 0.2V ; Auto-reset: 23V ± 0.5V
HIGH DC INPUT VOLTAGE
SHUTDOWN
16.5V ; Auto-reset: < 16.5V
33V ; Auto-reset: < 33V
SHORT CIRCUIT SHUTDOWN
When output voltage drops to 80V or lower for 1 to 1.5 sec
OVERLOAD SHUTDOWN
At overload of 110% to 115% for 2 to 2.5 sec
GROUND FAULT SHUTDOWN
Through GFCI outlets (5 to 6 mA leakage)
OVER TEMPERATURE SHUTDOWN
90°C ± 5°C (Sensed at internal hot spot) ; Auto reset at 65°C ± 5°C
REVERSE POLARITY ON
DC INPUT SIDE
External / internal DC sides fuses will blow
REMOTE CONTROL
WIRED REMOTE CONTROL WITH
LED / LED DISPLAY
WIRED ON / OFF CONTROL
RC-200 (Sold separately) with 16.5’ cable
COOLING
FORCED AIR COOLING
2 Temperature controlled fans (Temperature is sensed at internal hot spot)
Fan ON at 55°C ± 3°C; Fan OFF at 45°C ± 3°C
COMPLIANCE
SAFETY
Intertek - ETL Listed. Conforms to ANSI/UL Standard 458 and certi
-
fied to CSA Standard C22.2 No. 107.1-01
EMI / EMC
fCC Part 15(B), Class B
ENVIRONMENT
WORKING ENVIRONMENT
Indoor use
OPERATING TEMPERATURE RANGE
-20˚C to 40˚C / -4˚f to 104˚f
-20˚C to 40˚C / -4˚f to 104˚f
RELATIVE HUMIDITY
Up to 85%, non condensing
DIMENSIONS
(W X
D X H), MM
263.0 x 468.2 x 105.6
263.0 x 468.2 x 105.6
(W X D X H), INCHES
10.35 x 18.43 x 4.16
10.35 x 18.43 x 4.16
WEIGHT
KG
7.1
7.1
LBS
15.6
15.6
NOTES:
1. All power ratings are specified for resistive load at Power Factor = 1.
2. All specifications given above are at ambient temperature of 25
°
C / 77
°
F.
3. Specifications are subject to change without notice