background image

Page 7

INSTALLATION & MAKING CONNECTIONS

1

115V AC output receptacles

2

Power on/off Switch

3

Green L.E.D. - Power output status

4

Red L.E.D. - Overload

5

Red L.E.D. - Over temperature

6

Input terminals 

(back of unit -not shown)

RED - Positive (+)
WHITE - Negative (-)

7

Cooling fan 

(back of unit - not shown)

8

Grounding lug 

(back of unit - not shown)

CAUTION!

Reverse polarity of input connection will blow the fuse inside the

inverter and may cause permanent damage. Please ensure that

the 

RED

 positive terminal is connected to the po)

terminal of the battery and the 

WHITE

 negative (-) terminal is

connected to the negative (-) terminal of the battery. 

Damage

due to reverse polarity  is not covered by warranty

.

2

1

3

4

5

Summary of Contents for PST-60S-24A

Page 1: ...PURE SINE WAVE MODEL PST 60S 24A DC AC INVERTERS OWNER S MANUAL Please read this manual before operating your inverter AC POWER SOURCE...

Page 2: ...afety Installation 3 Warning 4 Description Application 5 6 Installation 7 8 Making Connections 8 Operating the Inverter 9 Protections against abnormal conditions 10 Troubleshooting Guide 11 12 Specifi...

Page 3: ...inverter must be kept in a safe place out of the reach of children The inverter must not be operated in a damp or wet environment Air intake and outlets must not be blocked Ensure good ventilation Do...

Page 4: ...ing charged simultaneously the output voltage of the charging device will be fed to the inverter n Ensure that the charging voltage of the alternator has not been set above 30V n Do not use an unregul...

Page 5: ...utility supplied electricity b Inductive loads like microwaves and motors run faster quieter and cooler c Reduces audible and electrical noise in fans fluorescent lights audio amplifiers TV Fax answer...

Page 6: ...times their normal running power for initial starting Ensure that the starting power of these loads is not more than 1000 watts Please also note that the output power indi cated for microwave ovens i...

Page 7: ...7 Cooling fan back of unit not shown 8 Grounding lug back of unit not shown CAUTION Reverse polarity of input connection will blow the fuse inside the inverter and may cause permanent damage Please e...

Page 8: ...ry The red wire is positive and the black wire is negative Connect the red wire to the RED terminal of the inverter and the black wire to the WHITE terminal of the inverter Now connect the black wire...

Page 9: ...4 When running on full load for longer duration keep the vehicle s engine running to prevent batteries from discharg ing 5 5 CAUTION Do not start the vehicle s engine with the inverter in ON conditio...

Page 10: ...L E D will be off The red over load L E D will be lit Remove the overload short circuit condition Switch off the D C power with the on off switch and switch on again Unit will remain latched in shut...

Page 11: ...e sent for repair Input voltage at inverter terminals is below 20V due to discharged battery or excessive voltage drop in the cabling from the battery to the inverter Re charge the battery Ensure cabl...

Page 12: ...terminal is below 21 4V Check battery voltage Excessive voltage drop in the cable connection from battery to inverter Tighten connections and use thicker gauge cable 6 AWG On cranking the battery volt...

Page 13: ...urge for few seconds 1000 Watts 8 8 Low Battery Alarm 21 4 V 8 9 Low Battery Shutdown 20 V 8 10 Input Over Voltage Shut down 15 V 8 11 Operating Ambient Temp 0 40o C 5o C 8 12 Efficiency 85 8 13 Conne...

Page 14: ...Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyon...

Page 15: ...Attach Receipt Page 15...

Page 16: ...Version PST 60S 24A 081303 110 17 Fawcett Road Coquitlam B C Canada V3K 6V2 e mail samlex samlexamerica com website www samlexamerica com 1 800 561 5885...