Connect the DC Input Wire to the DC Input Connector.

(6)

Plug in the cigarette lighter plug of the DC Input Wire into the cigarette lighter 

socket.
When the LED Status Indicator

(2)

 light is green, the inverter’s AC Outlet

(3)

 and USB 

port

(1)

 will have voltage outputs.

Insert plug of your electrical appliance into the AC Outlet

(3)

 of the inverter.

Remove the inverter from the cigarette lighter socket when not in use.
The inverter is protected against the following abnormal conditions and will shut 
down under these conditions:

•  Overload & short circuit on the output side
•  Over temperature due to fan failure or due to lack of cool replacement air
•  Low DC input voltage
•  High DC input voltage

The inverter will automatically reset when the abnormal condition is removed.
The status of operation of the inverter is indicated by the LED Status indicator

(2)

 as 

given below:

 

leD Status

Inverter & USB Status Indicated

The LED is OFF

Fuse blown or no USB power 

Green Light

Inverter & USB normal

Orange Light

Inverter shutdown*

USB normal 

Red Light

Inverter shutdown*

No USB power 

 

*Inverter shutdown: Over Temperature, Over Voltage & Low Voltage

 

Cooling

The inverter has a fan for cooling. It is temperature controlled and will come on once 

the temperature of the hot spot inside the unit exceeds a preset temperature. Hence, 

the fan may not be on all the time. Place the unit in a cool, well ventilated space that 
has adequate cool replacement air (see Fig. 4).

4

5

 

3

OPERATIONAL GUIDELINES

Summary of Contents for PST-12S-12A

Page 1: ...Please read this manual before using your inverter 120 Watt DC AC Inverter Pure Sine Wave PST 12S 12A Owner s Manual ...

Page 2: ...ep away from children Never attempt to operate the inverter from any power source other than a 12V battery Make sure that the power consumption of the appliance or equipment you wish to operate is compatible with the capacity of the inverter When operating the inverter with a car or marine battery start the engine every 30 to 60 minutes and let it run for approximately 10 minutes to recharge the b...

Page 3: ...Fig 1 Front view 1 USB Charger 5V 500mA 2 LED Status Indicator 3 AC Outlet Fig 2 Rear view 4 Cooling Slots 5 DC Fuse 6 DC Input Connector 4 5 6 3 2 DESCRIPTIONS ...

Page 4: ...Fig 3 Plan elevations dimensions 7 Cooling Slots 7 Fig 4 Installation clearances for installation Cooling Slots Cooling Slots 4 2 DESCRIPTIONS ...

Page 5: ...lacement air Low DC input voltage High DC input voltage The inverter will automatically reset when the abnormal condition is removed The status of operation of the inverter is indicated by the LED Status indicator 2 as given below LED Status Inverter USB Status Indicated The LED is OFF Fuse blown or no USB power Green Light Inverter USB normal Orange Light Inverter shutdown USB normal Red Light In...

Page 6: ...Load Current 0 5 A Input current maximum 15A Low Battery Shut Down 10V Dimension L x W x H 190x105x30mm Inverter Weight 453g Fan Temperature Controlled USB Power 5V 0 1V 500mA Protections Low input voltage High input voltage Overload Short circuit SAFETY EN 60950 1 E Mark 10R 03 9956 EMC EN 55022 2006 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 EN 55024 1998 A1 2001 A2 2003 6 TECHNICAL SPE...

Page 7: ...by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation or hook up abuse or misuse of the equipment including exposure to excessive heat salt or fresh water spray or water immersion No other express warranty is hereby given and there are no warranties which extend beyond those described herein This warranty ...

Page 8: ...034 2009 096_PST 12S 12A_Feb 2010 T 604 525 3836 F 604 525 5221 e mail samlex samlexamerica com website www samlexamerica com 110 17 Fawcett Rd Coquitlam B C Canada V3K 6V2 ...

Reviews: