16 | SAMLEX AMERICA INC.
PV +
PV -
Bat +
Bat -
PV +
PV -
BAT +
BAT -
PV +
PV -
BAT +
BAT -
fig 8.2
ring
terminal for
battery end
fig 8.3
fork
terminal for
Controller end
fig 8.1 Wiring Layout
battery
Inline fuse
(See fig 8.4)
Solar Panel
Warning:
Be careful not to short the battery
Use inline, 10A AtC type Fuse with AtC Fuse Holder (Fig. 8.4) as close to the battery as possible.
fig 8.4
Inline ATC fuse Holder and ATC-10, 10a fuse
(Not Supplied)
ATC-10
10A fuse
fuse
Holder
4" Pigtails, AWG#12
Wiring from Solar Panel to Charge Controller
1. Determine the position of the solar panel on the rV roof. While positioning panels, avoid shading
of the solar panel by neighbouring obstacles such as vents, air-conditioners, TV antennas etc. As far
as possible, position the panels to minimize wiring distance between the solar panel and the Charge
Controller. Place the panel at least 8-10 inches away from the rV roof edges and leave sufficient space
to walk around the panel and access the mounting hardware.
2. Make sure the thickness of the roof at the installation location is at least ½” thick and the material
is strong enough to provide mechanical support to the solar panel and mounting hardware against
possible wind loading. Place the panel length-wise to reduce the effects of wind loading on the rV.
1. Negative wire with MC4 Female connector (marked “+”)
2. Positive wire with MC4 Male connector (marked “-”)
1
2
Fig. 8.5. Solar Panel Connecting Wires kit "SCW-20-2"
3. Solar Panel Connecting Wires kit "SCW-20-2" consisting of 2 pre-assembled, 20 ft, AWG #12, Positive
(+) & Negative (-) PV extension wires have been provided (see fig. 8.5). The wires have MC4 mating
connectors on one end for connecting to the solar panel & bare ends on the other side for connecting
to the Charge Controller. The wires are marked (+) & and (-) for identification of the polarity.
4. Please read Section 3 on connecting PV extension Wires to the panels.
sectIOn 8 |
wiring