OC12-90
OC24-50
OC24-80
OC48-40
Model
No.
Manual
Please read this manual before operating your batterycharger
Programmable
Batterycharger
PROFESSIONAL BATTERYCHARGER
Omnicharge
EN
Page 1: ...OC12 90 OC24 50 OC24 80 OC48 40 Model No Manual Please read this manual before operating your batterycharger Programmable Batterycharger PROFESSIONAL BATTERYCHARGER Omnicharge EN...
Page 2: ...COSTS OR EXPENSES WHETHER SPECIAL DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK...
Page 3: ...rogrammable battery charger MODELS OC12 90 OC24 50 OC24 80 OC48 40 Conforms to the requirements of the following Directives of the European Union EMC Directive 2004 108 EC The above product is in conf...
Page 4: ...10 2 4 2 Bottom side connections 11 2 5 Parallel operation 11 3 CONFIGURING THE BATTERY CHARGER 12 3 1 Selecting the correct charge program 12 3 2 Charge programs explained 14 4 GENERAL OPERATION 16 4...
Page 5: ...ion on our website The purpose of this owner s manual is to provide explanations and procedures for installing configuring and operating the battery charger The installation instructions are intended...
Page 6: ...ls 7x mounting screws CAUTION After unpacking check if the product shows any mechanical damage Never use the product when the enclosure shows any visual damage caused by harsh handling or when it has...
Page 7: ...explosion never use this product in locations where there is danger of gas or dust explosions or where ignition protected equipment is mandatory Never install the charger directly on top of the batter...
Page 8: ...ttery cable and fuse size for each model Using a smaller cable size or a longer cable will cause additional losses and may result in improperly charged batteries Fire and burning hazards are present i...
Page 9: ...ns Up to 3 battery banks can be connected to the charger Each output can supply the full rated charging current The total charging current of all 3 outputs combined will never exceed the maximum rated...
Page 10: ...an error mode When the error condition has been cleared this relay will de activate again Please make sure not to exceed the maximum relay contact rating of 60V and 5A to avoid damaging the relay or P...
Page 11: ...he same model can be connected in parallel in order to reach very high charge current levels This manual will not show any connection or operation details for paralleled charger systems Such details a...
Page 12: ...o edit or create your own battery charge programs CAUTION Invalid battery type settings can cause serious damage to your batteries and or connected battery loads Always consult your battery s document...
Page 13: ...alize voltage equalize not available Max bulk time 12hrs Max absorption time 12hrs Position 6 Empty Reserved for future use If selected anyway the charger will return a battery error Position 7 Empty...
Page 14: ...r 3b will be lit This stage will return the final 20 of charge to the battery The output voltage is kept at a constant level and the charge current decreases as a function of the battery s state of ch...
Page 15: ...in connected to the activated charger continuously without risk of overcharging When the battery temperature sensor is installed the charger automatically compensates the charge voltages against batte...
Page 16: ...battery charger Indicator mode Description Continuous green Power on normal mode Flashing red 1 flash per sec Battery error A battery error can appear for several reasons These are battery voltage is...
Page 17: ...e to deliver full rated output current Since no automatic charging programs are activated in this mode it can be used for constant voltage charging or operating the charger as a battery buffered power...
Page 18: ...loads The Omnicharge cannot automatically determine when to stop the equalization of a battery The user must monitor the battery s specific gravity throughout this process to determine the end of the...
Page 19: ...r charger wire contacts Tighten battery terminal screws Blown DC fuse Check battery fuse or internal charger output fuse located on charger PCB Very poor battery condition Replace battery The battery...
Page 20: ...bles See the DC cable size table in chapter 2 4 Battery load current is higher than the charger s output current Reduce or remove the battery load LED charger on is blinking red once per second batter...
Page 21: ...es per second high charger temperature error Airflow around the charger is obstructed Make sure there is at least 10 centimeters of clearance around the charger Remove any items placed on or over the...
Page 22: ...ut voltage output short circuit high temperature battery overcharging and reverse polarity fuse Indications Power on output current state of charge error DC output connections 4x M8 bolts AC input con...
Page 23: ...roduct and product malfunctioning Since SAMLEX cannot control the use and installation according to local regulations of their products the customer is always responsible for the actual use of these p...