Below are the usual treatment durations depending on the humidity of the wood to be treated.
Table of thickness and treatment duration
Thickness
Low humidity
(2-7%)
High humidity
(8-15%)
0-25 mm
2:30
2:00
25-50 mm
3:00
2:30
50-75 mm
6:00
5:00
75-100 mm
7:00
6:00
100-150 mm
8:30
7:30
150-200 mm
9:30
8:30
Indicated times have been obtained in laboratory tests and are shown for guidance. The ambient
temperature will influence the necessary duration of the treatment.
In general, the temperature of 60ºC can be considered as a lethal temperature measured inside the
wood.
The treatment needed to reach in high depth
(≥5cm)
can increase wood surface temperature to very
high temperatures. Confirm that the temperature is appropriate for the object you want to treat.
Precautions during treatment
Do not allow access to the work area to people or animals. Respect the safety distance of 12 meters
around the equipment.
If treatment needs to be stopped, tap the red button on the screen or press the emergency stop
button. Treatment will stop immediately.
Do not tamper with equipment wiring during operation.
Do not interrupt the power supply during treatment. If there is a power interruption, you must repeat
the treatment in full.
At the end of the treatment, be careful with the treated objects, their temperature will be elevated. It
may take several minutes for wood to dissipate heat.