Low 

 

Medium 

 

High 

 

 

Selection treatment duration 

Use the "+" and "

" buttons to increase or decrease the desired treatment duration in minutes and 

seconds. When treatment has started, the timer starts a countdown to indicate the remaining time. 

 

Start and stop treatment 

Press the green button to start the treatment with selected parameters. When treatment starts, the 
button will turn red and you can press it to stop treatment if necessary. 

 

Progress indicator 

At the bottom of the screen is a progress bar indicating the evolution in percentage of the ongoing 
treatment. 

If at any time it is necessary to stop the treatment, you can press the red stop button or press the 
emergency stop button as well. 

The equipment will not generate any type of microwave radiation if the remote control is not properly 
connected. Accidental disconnection of the remote control will instantly stop any treatment. 

 

Pre-treatment required checks 

Inspect thoroughly and confirm that all objects are safe and suitable for treatment. Check objects and 
identify any existing damage to properly inform the customer beforehand. It is recommended to take 
photographs as proof of existing damage before treatment. 

Be careful with coatings such as varnishes and paints as elevated temperatures could damage or alter 
them. Microwave radiation produces very rapid heating that could be harmful to some materials. 

Avoid radiating large metal objects such as structures, coatings or metal plates, both inside the wood 
and in the area behind the treated area. In general, nails, screws and small metal elements are not a 
problem, but it is recommended to have them properly located and pay special attention if sparks or 
clicks occur during treatment. When in doubt, avoid treating sensitive areas or areas with the presence 
of metals. 

Avoid  the  presence  of  people  and  animals  in  an  area  of  12m  around  the  main  unit  during  any 
treatment. If the treatment is to be carried out on a wall, floor or ceiling with neighbours on the other 

Summary of Contents for EcoWood

Page 1: ...rowave solution against xylophages Microwaves penetrate deeply and quickly into wood and kill insects at any stage of their life from egg to adult The new version of EcoWood is lighter and easier to u...

Page 2: ...and operation 7 Connections 7 Treatment setup 8 Treatment 8 User interface 8 Power selection 9 Selection treatment duration 10 Start and stop treatment 10 Progress indicator 10 Pre treatment required...

Page 3: ...itech EcoWood the physical solution by microwaves against xylophages in wood EcoWood is effective against any type of xylophagous insect such as termites or woodworm fungi moths worms Please read this...

Page 4: ...the wood and on its humidity and density The elimination of pests found inside the wood is achieved by radiation of microwaves on the cellular structure of the insect Microwave radiation is effective...

Page 5: ...he main unit is operated remotely Additionally the product includes a microwave leak detector that ensures that the user is always off the radiation hazard area The basic kit consists of the items sho...

Page 6: ...to 2 7m Tripod articulation Wheel kit for tripod Antenna extension 40cm Antenna 30x20cm Antenna 30x10cm Horizontal bend Vertical bend Product setup The following describes the steps to prepare the pro...

Page 7: ...three legs of the tripod completely and rest the tripod on the ground vertically leaving the extendable bar upwards The tripod has a lifting winch with brake that allows the equipment to be lifted eff...

Page 8: ...s the neighbour evacuates the adjacent area during the treatment Treatment Once the checks described in the previous section have been made and the main unit has been placed in its initial position we...

Page 9: ...ill be greater The duration of treatment is limited to a maximum of 16 minutes per session See the time guide Power selection Select the desired power by sliding the horizontal bar with your finger Po...

Page 10: ...ly stop any treatment Pre treatment required checks Inspect thoroughly and confirm that all objects are safe and suitable for treatment Check objects and identify any existing damage to properly infor...

Page 11: ...er etc Corrosive or hazardous chemicals bleaches cleaners etc Any type of object that can be damaged or deteriorated by heat This list of objects is not exhaustive All objects to be treated should be...

Page 12: ...e wood The treatment needed to reach in high depth 5cm can increase wood surface temperature to very high temperatures Confirm that the temperature is appropriate for the object you want to treat Prec...

Page 13: ...ustible flammable or explosive materials or objects that may become combustible flammable or explosive when in high temperatures should not be treated Keep any combustible flammable or explosive mater...

Page 14: ...vers Place the cable and device away from passage areas Do not bend or tighten the cable and do not use if it is damaged Do not attempt to open or repair the main unit yourself Doing so could cause ha...

Reviews: