Operation
24
7 Operation
7.1 Control and Display Panel
Control and Display Panel of SolarRiver inverter is shown as figure 18.
Figure 18 HMI Interface
There are 6 buttons: OK, ESC, UP, DOWN, RIGHT, LEFT.
OK button: confirm the selection.
ESC button: exit current screen or selection
Up button: move cursor to up selection or increase the values
DOWN button: move cursor to down or decrease the values.
RIGHT button: move cursor to right side or increase the backlight.
LEFT button: move cursor to left side or decrease the backlight.
There are two LEDS on the panel. Different LED status means inverter different working statutes.
Table 4 LED statutes
Wait: Inverter is checking in this state. If finds fault or error, will enter Fault or Permanent state.
normal
:
Inverter feeds AC current into grid. If any error or fault occurs, inverter will go to Fault State
or Permanent State.
fault
:
Inverter has checked some recoverable error. It can recover if the error disappears. If in Fault
State continually, you should check the inverter according to table 5.
permanent
:
Inverter has checked some unrecoverable error. You should take some measure or ask
for help.
When the inverter operates normally, user touch any button, then the backlight will be on, and inverter
will display home interface. If none key touched for 60 seconds, the backlight will be off. In next 10
seconds if still no operation the screen will back to home interface, otherwise the backlight will be
illuminated.
Note: After starting inverter and restoring the factory settings, LCD backlight will not shut down
automatically.
LED
green
red
flash
Wait state
Fault state
S o l a r R i v e r
ESC
OK
Home
2012-03-03 10
00
00
:
:
Press Esc to Main Menu
Power
Today
Total
0.0
W
0.0
KWh
0.0
KWh
=
=
~
208.4
V
205.9
V
1.045
kw
49.99
Hz
t
kwh
Green LED
Red LED
Buttons
LCD