Environment
582134110-2B0453-indA-EN.docx
27/10/2020
15
3
Environment
The equipment must be installed on a horizontal, stable and flat
ground (eg concrete slab).
Non-moving equipment must be mounted to the ground by suitable
fasteners (spit, screws, bolts, ...) to ensure their stability during use.
To avoid risks due to static electricity, the equipment and its
components must be earth ground.
In combination with a pneumatic motor, the hydraulics will
be earthed via the earth cable of this motor.
This earth cable
must be connected to a safe earth ground.
Have the earth ground continuity checked by a qualified
electrician. If the ground continuity is not assured, check
terminal, wire and grounding point. Never operate the
equipment without solving this problem.
Do not store
more flammable products than necessary
inside the work area.
These products must be stored in
approved containers
and
grounded.
Use only grounded
metal buckets
for the use of rinse
solvents.
Cartons and papers are to be banned
. Indeed they are very
bad conductors, even insulators.