SAMES KREMLIN
Page 71
Manual : 573.199.112
After reassemblying, fill up the pump with solvent and increase progressively the pressure to
maximum
setting up of the seals.
After half an hour, stop the pump and open the exhaust valve to depressurize.
Retighten the wetting-cup (4) by means of the wrench supplied with the pump in order to be in
accordance with the drawing. Comply with assembly dimension.
Before reassemblying the different components :
-
Clean the parts with the appropriate cleaning solvent.
-
Install the new seals if it is necessary after having lubricated them with PTFE grease.
-
Lubricate the piston and the inside of the cylinder to prevent from damaging the seals.
-
Install new parts if it is necessary.
Summary of Contents for PU 3000
Page 62: ...SAMES KREMLIN Page 50 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model Airless ...
Page 67: ...SAMES KREMLIN Page 55 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model 4 L 30 1 ...
Page 72: ...SAMES KREMLIN Page 60 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP model 4 L 53 1 ...
Page 78: ...SAMES KREMLIN Page 66 Manual 573 199 112 SPECIFICATIONS PU 3000 PUMP 4 L Flowmax 53 1 version ...