![SAMES KREMLIN Inorecip V User Manual Download Page 27](http://html1.mh-extra.com/html/sames-kremlin/inorecip-v/inorecip-v_user-manual_3699181027.webp)
Index revision : A
27
7140
5.2. Start and setup menu
Power is turned on by the switch on the back of the Inomotion and by pressing the on/off but-
ton on the front panel to activate the display. The main menu appears, and the operator can
then begin to set up the module (
On power-up, each axis connected to the Inomotion moves to its reference position. The LED
(11) should then turn green to confirm that the coder has been set up. One screen page for
each connected axis.
When an axis cannot reach its reference point, an error code appears on the left side of the
screen (
).
5.3. Configuration pages
5.3.1. Configuration main page
Pressing and holding the On/Off switch (
14
) for 2 seconds without making any changes on the
screen will switch to the "
Main Setup
" screen.
The keys (5) and (6) are used to move up and
down between the lines. Turn the setting rotating
button (10) to change the value of any line.
These parameters are set at the factory and only
need to be checked if necessary.
Parameters
Limits
Description
Dimmer
0/10
Screen brightness adjustment
Axis N°
0/8
Maximum number of axis that can be controlled
Language
ENG-TR-RU
Language Options
MSTR./SLV
Master/slave modes
Master
: the module is configured as "Master" in a
network where the operational parameters are
sent to other modules
Slave
in a network where operational parameters
are copied from a "
Master
" module