4.4. Connecting plug (7 pins C)
Connection to the controls of the atomizer (e.g. electro valve). It is possible to use the 4, 5 and 6-pins
(trigger copy for the PLC).
WARNING : This relay is for passing low currents. If a high current is used this contact can no
longer be used for low currents.
Example of a PLC cabling:
Cabling for "HV ON" signalling light,
N° of
pins
Signal
1
earth
2
phase 1, output protected
3
phase 2, output protected
4
common to trigger image relay
5
trigger image relay contact normally closed
6
trigger image relay contact normally open
7
not connected
1 to 7
GNM case
8
Inside GNM
9
Main supply output protected by fuses
10
PLC input
1 to 7
GNM case
8
Inside GNM
9
Main supply output protected by fuses
10
220 VAC or 110 VAC
11
Light on