Safety instructions
11
Injection hazards
"HIGH PRESSURE" technology requires the utmost care.
Operation can cause dangerous leaks. There is a risk of product injection
into exposed parts of the body, which can lead to serious injury and the
risk of amputation:
An injection of product into the skin or other parts of the
body (eyes, fingers ...) must be treated urgently by
appropriate medical care.
Do not look at the gun nozzle when it is under pressure.
Never direct the jet to another person.
Never attempt to stop the jet with the body (hands,
fingers...) or with rags or similar.
Fire hazards, explosion,
electric arc, static electricity
Improper grounding, insufficient ventilation, open flames or sparks can
cause an explosion or fire which could result in serious injury.
To avoid these risks, especially when using pumps, it is imperative:
To connect the equipment, the parts to be treated, the
cans of products and cleaners to the ground,
To ensure good ventilation,
Keep the work area clean and free of rags, papers, solvents,
Do not operate electrical switches in the presence of vapors
or during removal,
Immediately stop the application in the presence of arcs,
Store all liquids outside the work areas.
Use products whose flash point is as high as possible to avoid
any risk of formation of flammable gases and vapors
(consult the product safety data sheets).
To equip the drums with a lid to reduce the diffusion of gases
and vapors in the cabin.
It is forbidden to pump explosive materials
Summary of Contents for AZUR 72C160
Page 27: ...Presentation of the material 27 1 3 2 Chamber rod assembly Switch set Carter distributor...
Page 34: ...Equipment plans 34 6 Equipment plans Pump 72C160...
Page 35: ...Equipment plans 35 Wall mounted pump...
Page 36: ...Equipment plans 36 Pump 72C160 Cart...
Page 37: ...Equipment plans 37 Pump 72C160 Cart Hopper...
Page 38: ...Equipment plans 38 Fluid section C160...
Page 39: ...Equipment plans 39 Motor 7000 Stroke 120...
Page 40: ...Equipment plans 40 Air supply...
Page 41: ...Equipment plans 41 Filter...
Page 42: ...Equipment plans 42 Pump priming kit...
Page 43: ...Equipment plans 43 Hopper...
Page 67: ...Disassembly Reassembly Operation 67 Remove the motor hood...
Page 76: ...Disassembly Reassembly Operation 76 Sling on the lifting ring bracket Tools needed...
Page 78: ...Disassembly Reassembly Operation 78 Retract the motor shaft manually...
Page 79: ...Disassembly Reassembly Operation 79 Remove the 4 tie rods with a 19 mm wrench Tools needed 19...
Page 83: ...Disassembly Reassembly Operation 83 Remove the crankcase and protective foam from the motor...
Page 88: ...Disassembly Reassembly Operation 88 Remove the two exhaust mounts...
Page 106: ...Disassembly Reassembly Operation 106 Retrieve the piston seal Tools needed...
Page 136: ...Disassembly Reassembly Operation 136 Manually re enter the motor shaft...
Page 147: ...Disassembly Reassembly Operation 147 Make the pneumatic wiring of the distributor part...
Page 151: ...Disassembly Reassembly Operation 151 Make the pneumatic wiring of the upper part...
Page 160: ...Pneumatic Wiring 160 Indirect air control...
Page 170: ...Operations Dismantling Reassembling the C160 Fluid section 170 Remove the cover...
Page 179: ...Operations Dismantling Reassembling the C160 Fluid section 179 Manually remove the cover...
Page 202: ...Operations Dismantling Reassembling the C160 Fluid section 202 Put the cover on...
Page 207: ...Spare parts 207...
Page 208: ...Spare parts 208...
Page 218: ...Spare parts 218 17 3 Spare Parts Product Filter 3 4 Model 500 bar 7252 psi...