Index revision : B - September 2020
8
7132
WARNING :
This equipment must only be used in powdering locations according to standard EN 50050-2
and EN 16985. The equipment has to be used only within ventilated in order to reduce risks for
the health of the operators, fire or explosion. The efficiency of the extraction ventilation system
has to be daily checked.
Within explosive atmospheres produced by the spraying process, only appropriate explosion-
proof electrical equipment has to be used.
1 The operator must wear shoes according to standard EN ISO 20344 and the insulation
resistance measured must not exceed 100 M
Ω
.
2 The protective clothes, including gloves, must conform to standard EN 1149-5 and the
insulation resistance measured must not exceed 100 M
Ω
.
3 Using individual protection equipment will limit the risks of contact and/or inhalation of
toxic product, gas, vapours, fog or dusts that can be produced while using the equip-
ment. The user has to follow the coating product manufacturer’s recommendations.
4 Contact or inhalation of the products used with this equipment may be dangerous for
personnel (see: safety data sheets for the products used). The pressure coating material
or compressed air must not be directed at people or animals.
5
The parts to be painted must have a resistance to earth less than or equal to 1 MW
(measurement voltage of at least 500V or 1000V) (§6.2.2.4 in Standard EN 50050-2). This
must be checked regularly.
6 All conductive structures such as floors, powder spray station walls, ceilings, barriers, bar-
riers, parts to be painted, powder dispensing tank placed in or near the work area and
the ground terminal of the electro-pneumatic control module must be electrically
connected to the grounding system for protecting the power supply.
7 The floor on which the operator works must be dissipative (bare concrete floor or metal
grating). Never cover the floor with an insulating covering. In potentially explosive loca-
tions, floor assemblies must be dissipative in accordance with EN 61340-4-1.
8 Switch off the power supply to the Inobox before connecting the "Inogun M" gun.Before
disconnecting the gun, cut off the power supply to the Inobox (otherwise a malfunction
may occur).
9 IIt is essential to properly ventilate the spray booths to avoid any powder output and to
ensure a powder concentration below the lower explosive limit (LEL). The associated
equipment must be placed outside the hazardous areas and its commissioning must be
controlled by the operation of the cabin suction fan.
10 Never point the gun at a person or animal.
11 Powder spraying must be carried out in front of a ventilated station provided for this
purpose. The activation of the Inobox must be controlled by the operation of the venti-
lation system. The correct operation of the drive must be checked once a week.