Connecting the RJ 45 plug (Ex-d or non-ex)
Strip off 25 cm of the cable isolation as described in chapter 3.1. Please make sure not to
damage the isolation foil (7).
The plug is connected according to EIA/TIA-568B (q.v. attached sketch).
The cables of the same color will be put through the applicable opening and then cut off
flush at the front. It is important that the shielding is lead through until it touches the
shielding clamp.
Figure 4.1
– Connecting the RJ 45 plug
With a gripper, press together the plug until it snaps and remove the piece of paper.
Figure 4.2
– Completed cable with a RJ 45 plug
For detailed instructions regarding the connection of the RJ 45 plug please refer to our
YouTube tutorial:
https://www.youtube.com/watch?v=LOJ_7drrn4E&feature=youtu.be