Doc.-ID: CableKitSKDP03-T_10M_MountingInstructions_rev.00.docx, Seite 4 von 12
2.1
Customization of the cable connection
Looking at the digital system cable
’s cross section, the following elements are visible:
Figure 2.1
– Cable cross section
Remove 10 cm of the wire
’s outer sheath (green jacket) (1) without damaging the wires.
Then cut off the white filling threads (2) and remove the white foil around the network ca-
bles (7) so that the shield is uncovered. In a next step, separate the shield by pulling out
the data elements (8) from the copper wire shielding (4) (see figure 2.2).
Figure 2.2
– Stripped cable and bare shielding
Cut off the five filling threads and the plastic foil. Make sure that the blank shielding wire
(5) is not removed. Twist this blank wire with the shielding (4) as shown below.
Figure 2.3
– Blank shielding wire and shielding braid
Blank shielding wire
Outer sheath (jacket) (1)
Filling threads (2)
Power elements (3)
Copper wire shielding (4)
Blank shielding wire (5)
Shielding foil (6)
Isolation foil (7)
Data elements (8)
(7)
(2)
(1)
(4)
(3)
Shielding wire + Shielding braid